Case Study: Correlations Between Curve Squeal, Weather Conditions, and Traction in a Tram Loop

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F24%3APU152589" target="_blank" >RIV/00216305:26210/24:PU152589 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.tribology.rs/journals/2024/2024-4/2024-4-12.html" target="_blank" >https://www.tribology.rs/journals/2024/2024-4/2024-4-12.html</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.24874/ti.1728.07.24.10" target="_blank" >10.24874/ti.1728.07.24.10</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Case Study: Correlations Between Curve Squeal, Weather Conditions, and Traction in a Tram Loop

  • Original language description

    This study explores the relationship between the coefficient of traction (CoT) and squeal noise parameters on a tram line loop, focusing on the influence of weather conditions. An automatic noise module was placed near a tram loop known for noise complaints. This module distinguishes between squeal and flange noise, recording their duration, root mean square (RMS) sound pressure level, and maximum sound pressure level when a threshold in the appropriate frequency band is exceeded. Concurrently, weather conditions were monitored, and the CoT on the rail was measured using a BUT rail tribometer. The findings reveal a notable correlation between the CoT and the duration of squeal noise, while the association with sound pressure levels was less pronounced. An increase in CoT was observed with rising relative humidity, which may be attributed to increasing temperature throughout a sunny April day, while absolute humidity remained almost constant. Furthermore, noise parameters rose with higher relative humidity and showed an inverse relationship with temperature. These findings suggest that weather conditions, particularly relative humidity and temperature, influence both the CoT and noise parameters on tram lines.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database

  • CEP classification

  • OECD FORD branch

    20301 - Mechanical engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Tribology in Industry

  • ISSN

    0354-8996

  • e-ISSN

  • Volume of the periodical

    46

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    RS - THE REPUBLIC OF SERBIA

  • Number of pages

    15

  • Pages from-to

    695-708

  • UT code for WoS article

  • EID of the result in the Scopus database

    2-s2.0-85212983772