All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Customized protective palatal obturator for intubation in newborns in cleft lip surgery: a randomized controlled trial

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26210%2F26%3A0198893" target="_blank" >RIV/00216305:26210/26:0198893 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216224:14110/25:00142208 RIV/65269705:_____/25:00082692

  • Result on the web

    <a href="https://www.tandfonline.com/doi/full/10.1080/07853890.2025.2561802" target="_blank" >https://www.tandfonline.com/doi/full/10.1080/07853890.2025.2561802</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1080/07853890.2025.2561802" target="_blank" >10.1080/07853890.2025.2561802</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Customized protective palatal obturator for intubation in newborns in cleft lip surgery: a randomized controlled trial

  • Original language description

    BackgroundOrofacial clefts are common congenital malformations, affecting both facial aesthetics and function. Intubation in newborns with cleft lip and palate is challenging and carries a high risk of oral tissue damage. This study investigates the use of a customized protective palatal obturator (CPPO) to improve intubation safety and reduce tissue injury during cleft lip surgery.MethodsA single-center, randomized neonatal sub-study was conducted, including 55 newborns who underwent cleft lip surgery. Patients were randomized into an intervention group (CPPO use) and a control group (standard intubation without CPPO). The primary aim was to evaluate the degree of oral tissue injury during intubation, its severity, and location, in both groups, secondary aims included laryngoscopy image during intubation (modified Cormack-Lehane scoring system), intubation time, and attempts, number of intubations attempts and anesthesiologic complication during intubation. This study was registered on www.clinicaltrials.gov (ClinicalTrials.gov Identifier: NCT04422847 and NCT04422964).ResultsNo tissue damage occurred in the CPPO group, while the control group had a 21.4% incidence of tissue injury (p = .023). Secondary outcomes showed no statistically significant differences between groups for intubation time or the number of intubation attempts. Difficult intubation was less frequent in the CPPO group (40.7%) compared to the control group (50%), though this difference was not statistically significant.ConclusionThe CPPO significantly reduces the risk of tissue damage during intubation in newborns undergoing cleft lip surgery, without increasing intubation time or attempts. It is particularly beneficial for severe clefts, and its use may facilitate safer airway management in these high-risk patients.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30218 - General and internal medicine

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    ANNALS OF MEDICINE

  • ISSN

    0785-3890

  • e-ISSN

    1365-2060

  • Volume of the periodical

    57

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    SE - SWEDEN

  • Number of pages

    11

  • Pages from-to

  • UT code for WoS article

    001576417500001

  • EID of the result in the Scopus database

    2-s2.0-105016768265