All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

A Comparison of AE Sensor Calibration Methods

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F08%3APU80701" target="_blank" >RIV/00216305:26220/08:PU80701 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    A Comparison of AE Sensor Calibration Methods

  • Original language description

    The paper reviews the background of the primary calibration of acoustic emission (AE) sensors and the determination of uncertainty in the calibration. The main sources of uncertainty in practical usage of calibration results are discussed. The comparisonof the results of the reciprocity primary calibration, step-force and reciprocity calibration with broadband-pulse excitation method is presented. The shape of calibration characteristics corresponds well up to 300 kHz. The calculation of the uncertainty in all the calibration methods is described. The problem of propagation of uncertainty in the fast Fourier algorithm was solved. Uncertainty of measurement by primary calibration is determined and the influence of selected sources of uncertainty for each used method of calibration is presented and practically measured results are discussed. Piezoelectric AE sensor PAC UT1000 was used as the sensor under test. The big influence on uncertainty in calibrations was the influence of remount

  • Czech name

    Srovnání metod kalibrace snímačů akustické emise

  • Czech description

    Článek shrnuje pozadí primární kalibrace snímačů akustické emise a určení nejistoty této kalibrace. Je zde diskutován cíl a smysl primární kalibrace a hlavní zdroje nejistoty v praktickém použití při kalibraci snímačů. Porovnání výsledků z obou metod jeprezentováno.

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JB - Sensors, detecting elements, measurement and regulation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA101%2F06%2F1689" target="_blank" >GA101/06/1689: A Model Component Analysis of the Acoustic Emission System</a><br>

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2008

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of Acoustic Emission

  • ISSN

    0730-0050

  • e-ISSN

  • Volume of the periodical

    2008

  • Issue of the periodical within the volume

    26

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    11

  • Pages from-to

  • UT code for WoS article

  • EID of the result in the Scopus database