An effect of a wide area compensated distribution network operation to touch voltage at the point of DTS which is connected to LV earthing system

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F11%3APU95094" target="_blank" >RIV/00216305:26220/11:PU95094 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Vliv provozu kompenzované sítě velkého rozsahu na velikost dotykového napětí u DTS se společným uzemněním

  • Original language description

    This contribution is focused on evaluation of touch voltage quantity during a permanent ground fault in compensated distribution network with wide size of capacitive current 812 A. The touch voltage was evaluated near distribution transformer station 22/0.4 kV with the earthing system interconnected with the earthing of the neutral conductor of the LV network (0.4 kV). The data were recorded during real experiment, where low-impedance and arcing ground faults occurred. The fault was performed by conductive connection between faulty phase and iron part of the station which is connected to its earthing system. In this case, the fault current could achieve maximum quantity. (Influence of compensated distribution network operation with wide range on a touch voltage)

  • Czech name

    Vliv provozu kompenzované sítě velkého rozsahu na velikost dotykového napětí u DTS se společným uzemněním

  • Czech description

    This contribution is focused on evaluation of touch voltage quantity during a permanent ground fault in compensated distribution network with wide size of capacitive current 812 A. The touch voltage was evaluated near distribution transformer station 22/0.4 kV with the earthing system interconnected with the earthing of the neutral conductor of the LV network (0.4 kV). The data were recorded during real experiment, where low-impedance and arcing ground faults occurred. The fault was performed by conductive connection between faulty phase and iron part of the station which is connected to its earthing system. In this case, the fault current could achieve maximum quantity. (Influence of compensated distribution network operation with wide range on a touch voltage)

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/ED0014%2F01%2F01" target="_blank" >ED0014/01/01: Research and Technology Centre of Renewable Energy Sources</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 6th International Scientific Symposium on Electrical Power Engineering Elektroenergetika 2011

  • ISBN

    978-80-553-0724-4

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    253-257

  • Publisher name

    Technická univerzita Košice, Katedra elektroenergetiky

  • Place of publication

    Mäsiarska 74 042 00 Košice

  • Event location

    Stará Lesná

  • Event date

    Sep 21, 2011

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article