Short Circuit Current in the Loaded Synchronous Generator

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F12%3APU98579" target="_blank" >RIV/00216305:26220/12:PU98579 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    čeština

  • Original language name

    Zkratový proud v zatíženém synchronním generátoru

  • Original language description

    This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transient state and the last part is a steady state. These states compose a total equation of short circuit current together and are calculated by a derivate equation on base of induced voltages, a d-q axis reactance and machine parameters. These currents are not a problem to measure in the small machines but these currents are easier to calculate in the machines with nominal power MVA and bigger. It is im-portant to know generator time constants and all reactances (d-q axis). The Induced voltages are derived from generator currents and voltages in this paper too.

  • Czech name

    Zkratový proud v zatíženém synchronním generátoru

  • Czech description

    This paper deals with the short circuit current calculation of the load synchronous generator. The short circuit current equation is compounded of the three parts. The first part of the time behavior is a subtransient state, the second part is a transient state and the last part is a steady state. These states compose a total equation of short circuit current together and are calculated by a derivate equation on base of induced voltages, a d-q axis reactance and machine parameters. These currents are not a problem to measure in the small machines but these currents are easier to calculate in the machines with nominal power MVA and bigger. It is im-portant to know generator time constants and all reactances (d-q axis). The Induced voltages are derived from generator currents and voltages in this paper too.

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/FR-TI1%2F068" target="_blank" >FR-TI1/068: *Generators for Gas Engines</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proccedings of the 13th International Scientific Conference Electric Power Engineering 2012

  • ISBN

    978-80-214-4514-7

  • ISSN

  • e-ISSN

  • Number of pages

    1390

  • Pages from-to

    1-4

  • Publisher name

    VUT, FEKT, UEEN

  • Place of publication

    Brno

  • Event location

    Brno

  • Event date

    May 23, 2012

  • Type of event by nationality

    EUR - Evropská akce

  • UT code for WoS article