Simultaneous electrical and fluorescence recording of HL-1 cells’ electrical activity in response to extracellular calcium stimulation
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F18%3APU129244" target="_blank" >RIV/00216305:26220/18:PU129244 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.22489/CinC.2018.103" target="_blank" >http://dx.doi.org/10.22489/CinC.2018.103</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.22489/CinC.2018.103" target="_blank" >10.22489/CinC.2018.103</a>
Alternative languages
Result language
angličtina
Original language name
Simultaneous electrical and fluorescence recording of HL-1 cells’ electrical activity in response to extracellular calcium stimulation
Original language description
In current cell tissue engineering and cardiology, beating models with behavior and properties similar to humans are necessary. The cardiac muscle HL-1 cells, whose genes have a parent with adult atrial myocytes, serve as a suitable model. HL-1 cells were seeded on a 120-electrode microelectrode (MEA) chamber and transient transfection of Accelerated Sensor of Action Potentials 1 (ASAP1), a genetically encoded voltage indicator, was performed. Simultaneous electrical and optical recording of cardiac cell culture electrical activity was made when the cells started to produce spontaneous action potentials. Recording synchronization was made using TTL pulses. Results showed that HL-1 cells start to produce asynchronous spontaneous action potentials (-375±10 µV) when reaching 90% MEA chamber confluency and which become periodical addition of extracellular calcium (-501±14 µV, 2.1±1.0 Hz). The ASAP1’s fluorescent response reached up to 21±5% ΔF/F. The time constant between detection of electrical and fluorescent response (τe/o) was determined as 12±5 ms.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Computing in Cardiology 2018
ISBN
—
ISSN
2325-887X
e-ISSN
—
Number of pages
4
Pages from-to
1-4
Publisher name
Computing in Cardiology
Place of publication
Maastricht, Netherlands
Event location
Maastricht
Event date
Sep 23, 2018
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000482598700162