All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

General methodology of the in-field diagnostic and localization of noise source in G3-PLC network

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F23%3APU148147" target="_blank" >RIV/00216305:26220/23:PU148147 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/10104173" target="_blank" >https://ieeexplore.ieee.org/document/10104173</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/ISPLC57122.2023.10104173" target="_blank" >10.1109/ISPLC57122.2023.10104173</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    General methodology of the in-field diagnostic and localization of noise source in G3-PLC network

  • Original language description

    This paper proposes a general methodology on the topic of diagnostic and localization of noise source within the area of one transformer station based on G3–PLC technology in the Cenelec–A band (36–91 kHz). Different noise types and noise sources common for Narrowband-Power Line Communication (NB–PLC) are described together with the character of the measured communication channel - the cable between the junction box and the transformer station. Description of various measurement and analysis approaches is included. Present noise was evaluated by the drop of signal-to-noise ratio (SNR), by the measurement of data loss during the file transfer and by the spectral analysis of the power line with the spectrum analyzer and with the PLC analyzer. This article reveals a significant noise source that prevented the communication of hundreds of smart meters with the data concentrator (DC) located at the transformer station. The authors also propose a set of 4 mitigation solutions for this non-standard situation ordered by the time difficulty of implementation to this PLC network.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/VJ02010016" target="_blank" >VJ02010016: Application of Artificial Intelligence for Ensuring Cyber Security for Smart City</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    2023 IEEE International Symposium on Power Line Communications and its Applications (ISPLC)

  • ISBN

    978-1-6654-9135-8

  • ISSN

  • e-ISSN

  • Number of pages

    6

  • Pages from-to

    37-42

  • Publisher name

    PeerJ Inc.

  • Place of publication

    Manchester, United Kingdom

  • Event location

    Manchester

  • Event date

    Mar 21, 2023

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000994536900007