Estimating Continuous Blood Pressure from a Smartphone PPG Using 1D U–Net

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0191348" target="_blank" >RIV/00216305:26220/26:0191348 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Estimating Continuous Blood Pressure from a Smartphone PPG Using 1D U–Net

  • Original language description

    The development of new methods for non-invasive blood pressure (BP) monitoring is nowadays moving towards accessible and inexpensive cuffless devices (e.g. smartphone and smartwatch). This paper presents an experimental cuff-less measurement of BP using a smartphone. A photoplethysmographic (PPG) signal measured by a smartphone camera is used to estimate continous BP. Reference continuous BP was captured using Finapres NOVA device based on Penaz principle. This paper verifies the effect of input data personalization on the accuracy of BP estimation using 1D U-Net. Personalization consists in adding the information about age, gender, weight and height of the subject to the PPG signal. The study involves 56 measured subjects. The output of U-Net is continuous BP waveform, which accuracy is compared with reference using Mean Absolute Error (MAE). Personalized approach shows better results MAE = 8.28±6.29 mmHg than non-personalized approach with raw PPGs inputs where MAE = 10.06±7.12 mmHg. In the subsequent estimation of systolic BP (SBP) for the personalized U-Net input, the MAE was 8.45±5.21 mmHg, and in the estimation of diastolic BP (DBP), the MAE was 6.13±4.61 mmHg. Proposed method of non-invasive cuffless smartphone-based is promising and will be further developed to enable it is general and widespread use.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20601 - Medical engineering

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2024

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Computing in Cardiology 2024

  • ISBN

  • ISSN

  • e-ISSN

    2325-887X

  • Number of pages

    4

  • Pages from-to

  • Publisher name

  • Place of publication

  • Event location

    Karlsruhe

  • Event date

    Sep 8, 2024

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article