All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Modeling and Testing of a Phasor Measurement Unit Under Normal and Abnormal Conditions Using Real-Time Simulator

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0198491" target="_blank" >RIV/00216305:26220/26:0198491 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/en18143624" target="_blank" >https://doi.org/10.3390/en18143624</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/en18143624" target="_blank" >10.3390/en18143624</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Modeling and Testing of a Phasor Measurement Unit Under Normal and Abnormal Conditions Using Real-Time Simulator

  • Original language description

    Abnormal operations, such as faults occurring in an electrical power system (EPS), dis-rupt its balanced operation, posing potential hazards to human lives and the system’s equipment. Effective monitoring, control, protection, and coordination are essential to mitigate these risks. The complexity of these processes is further compounded by the presence of intermittent distributed energy resources (DERs) in active distribution networks (ADNs) with bidirectional power flow, which introduces a fast-changing dy-namic aspect to the system. The deployment of phasor measurement units (PMUs) within the EPS as highly responsive equipment can play a pivotal role in addressing these challenges, enhancing the system’s resilience and reliability. However, synchro-phasor measurement-based studies and analyses of power system phenomena may be hindered by the absence of PMU blocks in certain simulation tools, such as PSCAD, or by the existing PMU block in Matlab/Simulink R2021b, which exhibit technical limita-tions. These limitations include providing only the positive sequence component of the measurements and lacking information about individual phases, rendering them un-suitable for certain measurements, including unbalanced and non-symmetrical fault operations. This study proposes a new reliable PMU model in Matlab and tests it under normal and abnormal conditions, applying real-time simulation and control-ler-hardware-in-the-loop (CHIL) techniques.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/EH22_008%2F0004617" target="_blank" >EH22_008/0004617: Energy conversion and storage</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Energies

  • ISSN

  • e-ISSN

    1996-1073

  • Volume of the periodical

    18

  • Issue of the periodical within the volume

    13

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    26

  • Pages from-to

    1-26

  • UT code for WoS article

    001543330100001

  • EID of the result in the Scopus database

    2-s2.0-105011677517