All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Beam Distortion Due to Gold Fiducial Markers During Salvage High-Intensity Focused Ultrasound in the Prostate

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26230%2F17%3APU122854" target="_blank" >RIV/00216305:26230/17:PU122854 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1002/mp.12044" target="_blank" >http://dx.doi.org/10.1002/mp.12044</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/mp.12044" target="_blank" >10.1002/mp.12044</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Beam Distortion Due to Gold Fiducial Markers During Salvage High-Intensity Focused Ultrasound in the Prostate

  • Original language description

    Purpose: High intensity focused ultrasound (HIFU) provides a non-invasive salvage treatment option for patients with recurrence after external beam radiation therapy (EBRT). As part of EBRT the prostate is frequently implanted with permanent fiducial markers. To date, the impact of these markers on subsequent HIFU treatment is unknown. The objective of this work was to systematically investigate, using computational simulations, how these fiducial markers affect the delivery of HIFU treatment. Methods: A series of simulations was performed modelling the propagation of ultrasound pressure waves in the prostate with a single spherical or cylindrical gold marker at different positions and orientations. For each marker configuration, a set of metrics (spatial-peak temporal-average intensity, focus shift, focal volume) was evaluated to quantify the distortion introduced at the focus. An analytical model was also developed describing the marker effect on the intensity at the focus. The model was used to examine the marker's impact in a clinical setting through case studies. Results: The simulations show that the presence of the marker in the pre-focal region causes reflections which induce a decrease in the focal intensity and focal volume, and a shift of the maximum pressure point away from the transducer's focus. These effects depend on the shape and orientation of the marker and become more pronounced as its distance from the transducer's focus decreases, with the distortion introduced by the marker greatly increasing when placed within 5mm of the focus. The analytical model approximates the marker's effect and can be used as an alternative method to the computationally intensive and time consuming simulations for quickly estimating the intensity at the focus. A retrospective review of a small patient cohort selected for focal HIFU after failed EBRT indicates that the presence of the marker may affect HIFU treatment delivery. Conclusion

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10201 - Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8)

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    MEDICAL PHYSICS

  • ISSN

    0094-2405

  • e-ISSN

    2473-4209

  • Volume of the periodical

    44

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    28

  • Pages from-to

    679-693

  • UT code for WoS article

    000397401800034

  • EID of the result in the Scopus database

    2-s2.0-85015606325