All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

SIMULTANEOUS DETERMINATION OF METAL TRACES USING SPE PRECONCENTRATION ON AMBERLITE XAD-7 BY ICP-MS IN ENVIRONMENTAL WATERS AND SAMPLES ECOTOXICOLOGY ASSESSMENT OF WATER SMAPLES AFTER MINING AND PROCESSING OF URANIUM

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F11%3APU97585" target="_blank" >RIV/00216305:26310/11:PU97585 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    SIMULTANEOUS DETERMINATION OF METAL TRACES USING SPE PRECONCENTRATION ON AMBERLITE XAD-7 BY ICP-MS IN ENVIRONMENTAL WATERS AND SAMPLES ECOTOXICOLOGY ASSESSMENT OF WATER SMAPLES AFTER MINING AND PROCESSING OF URANIUM

  • Original language description

    Direct determination of extremely low concentrations of trace elements by modern spetroscopic methods is often difficult. Limitations are associated not only with insufficient sensitivity of analytical equipments, but especially with matrix interference.For this reason, preconcentration and separation of trace elements from matrix are required. This study has been conducted for the determination of nine trace elements (Be, V, Co, Ni, Y, Cd, Pb, Th and U) by inductively coupled plasma mass spectromentry(ICP-MS) in natural waters and water samples after mining and processing of uranium. An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output 1500 W and concentric nebulizer MicroMist with a cooled Scott chamber was used. The nonspectral interferences were eliminated by using a solution of internal standards 6Li for 9Be, 45Sc (51V), 72Ge (59Co, 60Ni, 89Y), 103Rh (111Cd), 209Bi (206Pb, 207Pb, 208Pb, 232Th). The spectral interferences were eliminated by us

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2011

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů