All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

High-Resolution Ultrasonic Spectroscopy: Looking at the Interpolyelectrolyte Neutralization from a Different Perspective

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F23%3APU147885" target="_blank" >RIV/00216305:26310/23:PU147885 - isvavai.cz</a>

  • Result on the web

    <a href="https://pubs.acs.org/doi/10.1021/acs.macromol.2c02349" target="_blank" >https://pubs.acs.org/doi/10.1021/acs.macromol.2c02349</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1021/acs.macromol.2c02349" target="_blank" >10.1021/acs.macromol.2c02349</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    High-Resolution Ultrasonic Spectroscopy: Looking at the Interpolyelectrolyte Neutralization from a Different Perspective

  • Original language description

    In this study, the high-resolution ultrasonic spectroscopy (HR-US) technique was applied to examine interpolyelectrolyte neutralization. The mentioned method was tested on the example of complexation between poly(allylammonium) cations and poly(acrylate) anions in aqueous solutions at pH = 7. It was confirmed by HR-US that the type of titration (stepwise or abrupt), the direction of titration, and the type of background salt affect the outcome of interpolyelectrolyte neutralization. The obtained results were explained on the basis of ultrasonic velocity and attenuation changes in the context of suspension compressibility, a parameter that is extremely sensitive to molecular organization and intermolecular interactions. Moreover, the results of HR-US measurements proved to be consistent with previous results obtained by more traditional methods such as dynamic light scattering, microcalorimetry, and electrokinetics. This research demonstrates that HR-US is a convenient and reliable method that can be employed for the investigation of interpolyelectrolyte neutralization and polyelectrolyte-related processes.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10403 - Physical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Macromolecules

  • ISSN

    0024-9297

  • e-ISSN

    1520-5835

  • Volume of the periodical

    56

  • Issue of the periodical within the volume

    4

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    12

  • Pages from-to

    1434-1445

  • UT code for WoS article

    000935729400001

  • EID of the result in the Scopus database

    2-s2.0-85148439576