Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU138222" target="_blank" >RIV/00216305:26620/20:PU138222 - isvavai.cz</a>
Result on the web
<a href="https://iopscience.iop.org/article/10.1088/2057-1976/abc099/meta" target="_blank" >https://iopscience.iop.org/article/10.1088/2057-1976/abc099/meta</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/2057-1976/abc099" target="_blank" >10.1088/2057-1976/abc099</a>
Alternative languages
Result language
angličtina
Original language name
Electromechanical impedance measurements for bone health monitoring through teeth used as probes of a Piezo-device
Original language description
Bone is a dynamic biological tissue that acts as the primary rigid support of the body. Several systemic factors are responsible for pathologies that negatively affect its structural attributes. Although the bone is in continuous renewal by osteogenesis, metabolic diseases are the most common affectations that alter its natural equilibrium. Different techniques based on ionizing radiation are used for the bone diagnosis restrictively. However, if these are not used adequately, the application could present risks for human health. In this paper, it is proposed and explored a new technique to apply an early-stage diagnosis of bone variations. The technique evaluates bone structural conditions from the teeth (used as probes) by applying a structural health monitoring (SHM) methodology. An experimental procedure is described to identify the stiffness variations produced by mechanical drillings done in prepared bone samples. The identification is carried out applying the electromechanical impedance technique (EMI) through a piezo-actuated device in the frequency spectrum 5–20kHz. Three bone samples with incorporated teeth (three teeth, two teeth, and one tooth) were prepared to emulate a mandibular portion of alveolar bone-PDL (periodontal ligament)-tooth system. Piezo-device was attached to the crown of the tooth with an orthodontic bracket allowing the teeth to act as probes. The electrical resistance measurements were computed with an electrical decoupling approach that improved the detection of the drillings; it was due to the increment of the sensitivity of the signals. The results showed that the bone mass reduction is correlated with statistical indices obtained in specific frequency intervals of the electrical resistance. This work suggests the possibility of a future application addressed to a bone diagnosis in a non-invasive way.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30502 - Other medical science
Result continuities
Project
<a href="/en/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical Physics & Engineering Express
ISSN
2057-1976
e-ISSN
—
Volume of the periodical
7
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
11
Pages from-to
1-11
UT code for WoS article
000595516900001
EID of the result in the Scopus database
—