Bio-structural monitoring of bone mineral alterations through electromechanical impedance measurements of a Piezo-device joined to a tooth
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081723%3A_____%2F20%3A00533707" target="_blank" >RIV/68081723:_____/20:00533707 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/20:PU137621
Result on the web
<a href="https://link.springer.com/article/10.1007/s13534-020-00170-9" target="_blank" >https://link.springer.com/article/10.1007/s13534-020-00170-9</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s13534-020-00170-9" target="_blank" >10.1007/s13534-020-00170-9</a>
Alternative languages
Result language
angličtina
Original language name
Bio-structural monitoring of bone mineral alterations through electromechanical impedance measurements of a Piezo-device joined to a tooth
Original language description
Bone presents different systemic functionalities as calcium phosphate reservoir, organ protection, among others. For that reason, the bone health conditions are essential to keep in equilibrium the metabolism of several body systems. Different technologies exist to diagnose bone conditions with invasive methods based on ionizing radiation. Therefore, there is a challenge to develop new ways to evaluate bone alterations in a noninvasive form. This study shows the assessment of a piezo-actuated device acting on a human tooth for the bio-monitoring of bone alterations. The bone diagnosis is performed by applying the electromechanical impedance technique (EMI), commonly used in structural health monitoring. For the experimental tests, five bone samples were prepared, and one was chosen as the monitoring. All samples were put in a decalcifying substance (TBD1 acid-base) at different times to emulate localized bone mineral alterations. Bone reductions were computed by using X-ray micro-computed tomography analyzing the morphometry. Electrical resistance measurements (piezo-device) were taken for the monitoring specimen meanwhile it was partially decalcified during 8520 seconds. In the frequency spectrum, several observation windows showed that the bone alterations gradually changed the electrical resistance signals which were quantified statistically. Results evidenced that the bone density changes are correlated with the electrical resistance measurements, these changes presented an exponential behavior as much as in the calculated index, and bone mineral reduction. The results demonstrated that bone alterations exhibit linear dependence with the computed statistical indexes. This result confirms that it is possible to observe the bone changes from the teeth as a future application.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20205 - Automation and control systems
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical Engineering Letters
ISSN
2093-9868
e-ISSN
—
Volume of the periodical
10
Issue of the periodical within the volume
4
Country of publishing house
GB - UNITED KINGDOM
Number of pages
15
Pages from-to
603-617
UT code for WoS article
000571368900001
EID of the result in the Scopus database
2-s2.0-85091130278