Effect of detector in-plane rotation misalignment on dimensional measurements using helical CT acquisition
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F22%3APU145374" target="_blank" >RIV/00216305:26620/22:PU145374 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/21:PU142583
Result on the web
<a href="http://www.ndt.net/?id=26607" target="_blank" >http://www.ndt.net/?id=26607</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Effect of detector in-plane rotation misalignment on dimensional measurements using helical CT acquisition
Original language description
One of the critical factors that may significantly contribute to X-ray computed tomography measurement uncertainty is the misalignment of CT system components from ideal geometry assumed by tomographic reconstruction. It is proven to cause image artifacts, inhomogeneous magnification, thus leading to dimensional measurement errors. There is a lack of studies on helical trajectory scanning in metrological applications, focusing on the detector's angular misalignments. We will present results of CT measurements with misaligned detector by in-plane rotation for circular, double-helix, and space-filling trajectory. They prove that such misalignment may cause significant measurements errors, depending on the misalignments magnitude and applied acquisition trajectory.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
—
OECD FORD branch
20301 - Mechanical engineering
Result continuities
Project
<a href="/en/project/LM2018110" target="_blank" >LM2018110: CzechNanoLab research infrastructure</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů