A mid-infrared lab-on-a-chip for dynamic reaction monitoring
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F22%3APU147100" target="_blank" >RIV/00216305:26620/22:PU147100 - isvavai.cz</a>
Result on the web
<a href="https://www.nature.com/articles/s41467-022-32417-7" target="_blank" >https://www.nature.com/articles/s41467-022-32417-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1038/s41467-022-32417-7" target="_blank" >10.1038/s41467-022-32417-7</a>
Alternative languages
Result language
angličtina
Original language name
A mid-infrared lab-on-a-chip for dynamic reaction monitoring
Original language description
Mid-infrared spectroscopy is a sensitive and selective technique for probing molecules in the gas or liquid phase. Investigating chemical reactions in bio-medical applications such as drug production is recently gaining particular interest. However, monitoring dynamic processes in liquids is commonly limited to bulky systems and thus requires time-consuming offline analytics. In this work, we show a next-generation, fully-integrated and robust chip-scale sensor for online measurements of molecule dynamics in a liquid solution. Our fingertip-sized device utilizes quantum cascade technology, combining the emitter, sensing section and detector on a single chip. This enables real-time measurements probing only microliter amounts of analyte in an in situ configuration. We demonstrate time-resolved device operation by analyzing temperature-induced conformational changes of the model protein bovine serum albumin in heavy water. Quantitative measurements reveal excellent performance characteristics in terms of sensor linearity, wide coverage of concentrations, extending from 0.075 mg ml(-1) to 92 mg ml(-1) and a 55-times higher absorbance than state-of-the-art bulky and offline reference systems. Rapid investigation of chemical reactions is a challenge in bio-medical analysis. Here, the authors demonstrate sensitive in-situ real-time reaction-monitoring of conformational changes in protein solution, based on a fingertip-sized mid-IR lab-on-a-chip.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10700 - Other natural sciences
Result continuities
Project
<a href="/en/project/LM2018110" target="_blank" >LM2018110: CzechNanoLab research infrastructure</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
NATURE COMMUNICATIONS
ISSN
2041-1723
e-ISSN
—
Volume of the periodical
13
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
„“-„“
UT code for WoS article
000840338100013
EID of the result in the Scopus database
2-s2.0-85135946654