All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Factors influencing the accuracy of non-invasive blood pressure measurements in patients admitted for cardiogenic shock

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F19%3A10394765" target="_blank" >RIV/00669806:_____/19:10394765 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11140/19:10394765

  • Result on the web

    <a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=63GQpMuFG4" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=63GQpMuFG4</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1186/s12872-019-1129-9" target="_blank" >10.1186/s12872-019-1129-9</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Factors influencing the accuracy of non-invasive blood pressure measurements in patients admitted for cardiogenic shock

  • Original language description

    Background: Although invasively measured blood pressure (invBP) is regarded as a &quot;gold standard&quot; in critically ill cardiac patients, the non-invasive BP is still widely used, at least at the initiation of medical care. The erroneous interpretation of BP can lead to clinical errors. We therefore investigated the agreement of both methods with respect to some common clinical situation. Methods: We included 85 patients hospitalized for cardiogenic shock. We measured BP every 6 h for the first 72 h of hospitalization, in all patients. Each set of BP measurements included two invasive (invBP), two auscultatory (auscBP), and two oscillometric (oscBP) BP measurements. InvBP was considered as a gold standard. Mean non-invasive arterial pressure (MAP) was calculated as (diastolic pressure + (pulse pressure ÷ 3)). We used Bland-Altman analysis and we calculated concordance correlation coefficients to assess agreement between different BP methods. Results: We obtained 967 sets of BP measurements. AuscMAP and oscMAP were on average only 0.4 +- 8.2 and 1.8 +- 8.5 mmHg higher than invMAP, respectively. On the other hand, auscSBP and oscSBP were on average - 6.1 +- 11.4 and - 4.1 +- 9.8 mmHg lower than invSBP, respectively. However, the mean differences and variability for systolic and diastolic BP variability were large; the 2 standard deviation differences were +- 24 and 18 mmHg. In hypotension, non-invasive BP tended to be higher than invBP while the opposite was true for high BP values. Clinical conditions associated with hypotension generally worsened the accuracy of non-invasive MAP. Conclusions: Mean arterial pressure measured non-invasively appears to be in good agreement with invasive MAP in patients admitted for cardiogenic shock. Several clinical associated with hypotension can affect accuracy of non-invasive measurement. Auscultatory and oscillometric measurements had similar accuracy even in patients with arrhythmia.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30201 - Cardiac and Cardiovascular systems

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    BMC Cardiovascular Disorders

  • ISSN

    1471-2261

  • e-ISSN

  • Volume of the periodical

    19

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    10

  • Pages from-to

    150

  • UT code for WoS article

    000472020500002

  • EID of the result in the Scopus database

    2-s2.0-85067600126