Factors influencing the accuracy of non-invasive blood pressure measurements in patients admitted for cardiogenic shock
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F19%3A10394765" target="_blank" >RIV/00669806:_____/19:10394765 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/19:10394765
Result on the web
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=63GQpMuFG4" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=63GQpMuFG4</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1186/s12872-019-1129-9" target="_blank" >10.1186/s12872-019-1129-9</a>
Alternative languages
Result language
angličtina
Original language name
Factors influencing the accuracy of non-invasive blood pressure measurements in patients admitted for cardiogenic shock
Original language description
Background: Although invasively measured blood pressure (invBP) is regarded as a "gold standard" in critically ill cardiac patients, the non-invasive BP is still widely used, at least at the initiation of medical care. The erroneous interpretation of BP can lead to clinical errors. We therefore investigated the agreement of both methods with respect to some common clinical situation. Methods: We included 85 patients hospitalized for cardiogenic shock. We measured BP every 6 h for the first 72 h of hospitalization, in all patients. Each set of BP measurements included two invasive (invBP), two auscultatory (auscBP), and two oscillometric (oscBP) BP measurements. InvBP was considered as a gold standard. Mean non-invasive arterial pressure (MAP) was calculated as (diastolic pressure + (pulse pressure ÷ 3)). We used Bland-Altman analysis and we calculated concordance correlation coefficients to assess agreement between different BP methods. Results: We obtained 967 sets of BP measurements. AuscMAP and oscMAP were on average only 0.4 +- 8.2 and 1.8 +- 8.5 mmHg higher than invMAP, respectively. On the other hand, auscSBP and oscSBP were on average - 6.1 +- 11.4 and - 4.1 +- 9.8 mmHg lower than invSBP, respectively. However, the mean differences and variability for systolic and diastolic BP variability were large; the 2 standard deviation differences were +- 24 and 18 mmHg. In hypotension, non-invasive BP tended to be higher than invBP while the opposite was true for high BP values. Clinical conditions associated with hypotension generally worsened the accuracy of non-invasive MAP. Conclusions: Mean arterial pressure measured non-invasively appears to be in good agreement with invasive MAP in patients admitted for cardiogenic shock. Several clinical associated with hypotension can affect accuracy of non-invasive measurement. Auscultatory and oscillometric measurements had similar accuracy even in patients with arrhythmia.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BMC Cardiovascular Disorders
ISSN
1471-2261
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
1
Country of publishing house
GB - UNITED KINGDOM
Number of pages
10
Pages from-to
150
UT code for WoS article
000472020500002
EID of the result in the Scopus database
2-s2.0-85067600126