Accuracy analysis of the dose delivery process while using the Xsight® Spine Tracking technology

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F18%3AE0107550" target="_blank" >RIV/00843989:_____/18:E0107550 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1088/2057-1976/aae8d7" target="_blank" >http://dx.doi.org/10.1088/2057-1976/aae8d7</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/2057-1976/aae8d7" target="_blank" >10.1088/2057-1976/aae8d7</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Accuracy analysis of the dose delivery process while using the Xsight® Spine Tracking technology

  • Original language description

    The Accuray CyberKnife® system provides radiotherapy for the treatment of moving lung tumors, thanks to the use of the Xsight® Lung Tracking technology for monitoring the motion of the target. However, there are situations in which this technology is not able to properly track the target. Thus, the aim of the proposed work is to study the accuracy of the dose delivery process while using the Xsight® Spine Tracking technology, which helps to overcome the aforementioned issue. The CIRS Dynamic Thorax Phantom was used to simulate the motion of a spherical target (diameter 2 cm), which moves along the craniocaudal direction (motion 3 cm). Monte Carlo algorithm calculated PTV and ITV treatment plans for isocentric and non-isocentric irradiation methods. Ionization Chamber and Film Dosimetry measurements were performed to study the accuracy of the dose delivery process to the center, and to the periphery of the tumor. Results obtained through the implementation of the PTV treatment plans were used as a baseline to analyze the accuracy of dose delivery for ITV plans. Although results indicated a decrease for the dose delivered compared to the planned one, the dose delivered was not lower than the prescribed one in any of the studied cases.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30204 - Oncology

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Biomedical physics & engineering express

  • ISSN

    2057-1976

  • e-ISSN

  • Volume of the periodical

    4

  • Issue of the periodical within the volume

    065033)

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    12

  • Pages from-to

    1-12

  • UT code for WoS article

    000456881000034

  • EID of the result in the Scopus database

    2-s2.0-85056420645