Accuracy analysis of the dose delivery process while using the Xsight (R) Spine Tracking technology
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F18%3A10241740" target="_blank" >RIV/61989100:27240/18:10241740 - isvavai.cz</a>
Result on the web
<a href="https://iopscience.iop.org/article/10.1088/2057-1976/aae8d7/meta" target="_blank" >https://iopscience.iop.org/article/10.1088/2057-1976/aae8d7/meta</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/2057-1976/aae8d7" target="_blank" >10.1088/2057-1976/aae8d7</a>
Alternative languages
Result language
angličtina
Original language name
Accuracy analysis of the dose delivery process while using the Xsight (R) Spine Tracking technology
Original language description
The Accuray CyberKnife (R) system provides radiotherapy for the treatment of moving lung tumors, thanks to the use of the Xsight (R) Lung Tracking technology for monitoring the motion of the target. However, there are situations in which this technology is not able to properly track the target. Thus, the aim of the proposed work is to study the accuracy of the dose delivery process while using the Xsight (R) Spine Tracking technology, which helps to overcome the aforementioned issue. The CIRS Dynamic Thorax Phantom was used to simulate the motion of a spherical target (diameter 2 cm), which moves along the craniocaudal direction (motion 3 cm). Monte Carlo algorithm calculated PTV and ITV treatment plans for isocentric and non-isocentric irradiation methods. Ionization Chamber and Film Dosimetry measurements were performed to study the accuracy of the dose delivery process to the center, and to the periphery of the tumor. Results obtained through the implementation of the PTV treatment plans were used as a baseline to analyze the accuracy of dose delivery for ITV plans. Although results indicated a decrease for the dose delivered compared to the planned one, the dose delivered was not lower than the prescribed one in any of the studied cases.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20205 - Automation and control systems
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biomedical Physics and Engineering Express
ISSN
2057-1976
e-ISSN
—
Volume of the periodical
4
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
12
Pages from-to
—
UT code for WoS article
000456881000034
EID of the result in the Scopus database
2-s2.0-85056420645