All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109730" target="_blank" >RIV/00843989:_____/22:E0109730 - isvavai.cz</a>

  • Alternative codes found

    RIV/61988987:17110/22:A2302ITQ RIV/61989100:27360/22:10250246 RIV/61989100:27230/22:10250246

  • Result on the web

    <a href="https://www.mdpi.com/2076-3417/12/15/7470" target="_blank" >https://www.mdpi.com/2076-3417/12/15/7470</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/app12157470" target="_blank" >10.3390/app12157470</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures

  • Original language description

    This article focuses on a type of surgical implant used in orthopaedics and traumatology-cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30211 - Orthopaedics

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Applied sciences

  • ISSN

    2076-3417

  • e-ISSN

    2076-3417

  • Volume of the periodical

    12

  • Issue of the periodical within the volume

    15

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    16

  • Pages from-to

    1-16

  • UT code for WoS article

    000839100500001

  • EID of the result in the Scopus database

    2-s2.0-85136994938