Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F22%3AE0109730" target="_blank" >RIV/00843989:_____/22:E0109730 - isvavai.cz</a>
Alternative codes found
RIV/61988987:17110/22:A2302ITQ RIV/61989100:27360/22:10250246 RIV/61989100:27230/22:10250246
Result on the web
<a href="https://www.mdpi.com/2076-3417/12/15/7470" target="_blank" >https://www.mdpi.com/2076-3417/12/15/7470</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/app12157470" target="_blank" >10.3390/app12157470</a>
Alternative languages
Result language
angličtina
Original language name
Biomechanical assessment of cannulated nails for the treatment of proximal femur fractures
Original language description
This article focuses on a type of surgical implant used in orthopaedics and traumatology-cannulated femoral nails. Femoral nails are used in medical treatment for purposes of osteosynthesis, i.e., when treating various types of complicated fractures, in this case fractures of the femur. The article investigates cases in which a nail has been implanted in the proximal part of the femur for a short time (with the fracture still not healed), compared with cases in which the bone has already healed. According to AO classification, examined fractures are described as AO 31B3 AO 32A3. The main focus is on strength-deformation analysis using the finite element method (FEM), which makes it possible to determine the behaviour of the femur-implant system. FEM analysis was used to compare 1.4441 steel nails made by two manufacturers, Medin (Czech Republic) and Tantum (Germany). Boundary conditions including external loading, prescribed supports and elastic foundation are defined. There were solved FEM analyses for five cases of healed femur and five cases of broken femur both including implants with prescribed collo-diaphyseal angles. The results of the analysis were used to assess stress-deformation states from the perspective of appropriateness for clinical treatment, biomechanical reliability and safety. All examined femoral nails are compared, safe and suitable for patient treatment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Applied sciences
ISSN
2076-3417
e-ISSN
2076-3417
Volume of the periodical
12
Issue of the periodical within the volume
15
Country of publishing house
CH - SWITZERLAND
Number of pages
16
Pages from-to
1-16
UT code for WoS article
000839100500001
EID of the result in the Scopus database
2-s2.0-85136994938