Evaluation of UV, UV/H2O2 and UV/Na2S2O8 systems for the treatment of industrial waters – Organics degradation and disinfection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F15%3A%230001104" target="_blank" >RIV/26722445:_____/15:#0001104 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Evaluation of UV, UV/H2O2 and UV/Na2S2O8 systems for the treatment of industrial waters – Organics degradation and disinfection
Original language description
Organic molecules in a form of organic compounds and microorganisms, measured as Total Organic Carbon (TOC), can get into industrial water and cause severe problems in consequent technology (eg. organics fouling on system walls, biofoulings, corrosion, microbiologically influenced corrosion). One of possible methods for TOC decrease - organic compounds degradation and disinfection - is to use UV light. The UV light efficiency in degradation and disinfection process can be further enhanced by the presence of oxidizing agents (eg. H2O2, Na2S2O8). The main advantage of the suggested technology is that it is universal and non-selective and that it is ecologically friendly. In this paper, we experimentally tested the efficiency of UV, UV/H2O2 and UV/Na2S2O8 systems in TOC decrease. The experiments were performed in a continuous mode with various flow rates of feed solution and oxidizing agents. As the feed solution, real samples of cooling water from various power plants (coal, nuclear) were used. The samples of water were analyzed before and after each experiment to determine TOC and microbiological indicators of water quality. In microbiological analyses we focused on the presence of culturable microorganisms (at 22 °C and 36 °C), coliforms and E. coli, enterococci, Pseudomonas aeruginosa (biofilms, sliming), Clostridium perfringens (anaerobic, endospores), Staphylococcus aureus (resistant to chemical treatment), algae and cyanobacteria. The results of experiments confirmed that UV light itself as well as in the combination with H2O2 or Na2S2O8 is an efficient method for the organics degradation and disinfection. From the experimental results, the best experimental setup for water treatment was suggested.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
CH - Nuclear and quantum chemistry, photo chemistry
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the 3rd Internati onal Conference on Chemical Technology
ISBN
978-80-86238-79-1
ISSN
—
e-ISSN
—
Number of pages
4
Pages from-to
341-344
Publisher name
Czech Society of Industrial Chemistry
Place of publication
Praha
Event location
Mikulov
Event date
—
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—