All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

TKD and STEM in SEM analysis of ODS steels from the DEHITERE project

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26722445%3A_____%2F23%3AN0000101" target="_blank" >RIV/26722445:_____/23:N0000101 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    TKD and STEM in SEM analysis of ODS steels from the DEHITERE project

  • Original language description

    The main advantage of TKD over conventional EBSD is its improved spatial resolution. This enables to characterize the nanocrystalline and deformed materials effectively. It also provides the crystal structure information of precipitates and second phase particles of sizes about ~10 nm and bigger. It is possible to obtain sub-10 nm resolution using TKD, however, it depends on the sample atomic number, beam energy, sample thickness and tilt angle which all influence the final spatial resolution. The samples prepared for TEM analysis can be used to perform TKD analysis. The ideal sample thickness to perform TKD scan is less than 100 nm. The below scan shown in Fig. 1(a), was performed on the fine-grained region of the ODS steel prepared from the electrolytic polishing method. Figure 1(b and c) indicates the typical maps (inverse pole figure and image quality map) obtained from the EBSD analysis. IPF map indicates that high angle grain boundaries are not completely evolved in the microstructure yet as low angle sub-grain boundaries can be observed in a few grains. The grain size varied from ~150 to 700 nm in the small scan performed. Another small scan on hydrided Zircaloy-4 is also performed, (see Fig. 2). This sample is prepared from the focused ion milling route. More unindexed points are found in this sample after the TKD scan is because of the highly deformed sample and different sample preparation route (it is unknown how different preparation route influence the indexing). Report CVR-5072.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

  • Continuities

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů