The Reproducibility Assessment of Black-White Pixels Ratio in Transcranial B-images of Medial Temporal Lobe in Application for Detectable Feature of Alzheimer's Disease
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26867184%3A_____%2F20%3AN0000036" target="_blank" >RIV/26867184:_____/20:N0000036 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1109/BIA50171.2020.9244520" target="_blank" >http://dx.doi.org/10.1109/BIA50171.2020.9244520</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/BIA50171.2020.9244520" target="_blank" >10.1109/BIA50171.2020.9244520</a>
Alternative languages
Result language
angličtina
Original language name
The Reproducibility Assessment of Black-White Pixels Ratio in Transcranial B-images of Medial Temporal Lobe in Application for Detectable Feature of Alzheimer's Disease
Original language description
The aim of this paper is analysis the black-white pixels ratio in medial temporal lobe (MTL) brain structure in digitized transcranial B-images using own developed software BMODE Assist. This ratio could be a corresponding marker with the echogenicity grade. In transcranial sonography, the MTL in B-image is anechogenic structure but increased echogenicity of surrounding cortex is detectable in the case of MTL atrophy which predicts Alzheimer's Disease. Totally of 97 B-images were analyzed. The goal is to verify the reproducibility in two. Firstly, between two observers and to show that the ratio is not significantly different between original image and a magnified segment. In parallel in the case of constant brightness increasing. The ratio should be independent on image resolution and brightness. To select MTL, a 20mm square-shaped Region of Interest is used. The correlation coefficient r =0.69 was achieved between two independent, non-experienced observers. Between two non-experienced observers the error of 27.95 % was achieved and between the measurements from the same observer the error was only 11.2 %. Meanwhile, the variance and the range were computed, both almost equal. These results have been judged by an experienced sonographer. In the future, the ratio could be an usable value to determine the MTL atrophy risk using the ratio value and possibility to create a rule-based expert system as a software tool to evaluate probability of Alzheimer's Disease using transcranial sonography.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
21100 - Other engineering and technologies
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the International Conference on Biomedical Innovations and Applications, BIA 2020
ISBN
9781728170732
ISSN
—
e-ISSN
—
Number of pages
5
Pages from-to
53-57
Publisher name
Technical University - Varna
Place of publication
Bulharsko
Event location
Bulharsko
Event date
Jan 1, 2020
Type of event by nationality
CST - Celostátní akce