All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Reproducibility Assessment of Black-White Pixels Ratio in Transcranial B-images of Medial Temporal Lobe in Application for Detectable Feature of Alzheimer's Disease

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F26867184%3A_____%2F20%3AN0000036" target="_blank" >RIV/26867184:_____/20:N0000036 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1109/BIA50171.2020.9244520" target="_blank" >http://dx.doi.org/10.1109/BIA50171.2020.9244520</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/BIA50171.2020.9244520" target="_blank" >10.1109/BIA50171.2020.9244520</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Reproducibility Assessment of Black-White Pixels Ratio in Transcranial B-images of Medial Temporal Lobe in Application for Detectable Feature of Alzheimer's Disease

  • Original language description

    The aim of this paper is analysis the black-white pixels ratio in medial temporal lobe (MTL) brain structure in digitized transcranial B-images using own developed software BMODE Assist. This ratio could be a corresponding marker with the echogenicity grade. In transcranial sonography, the MTL in B-image is anechogenic structure but increased echogenicity of surrounding cortex is detectable in the case of MTL atrophy which predicts Alzheimer's Disease. Totally of 97 B-images were analyzed. The goal is to verify the reproducibility in two. Firstly, between two observers and to show that the ratio is not significantly different between original image and a magnified segment. In parallel in the case of constant brightness increasing. The ratio should be independent on image resolution and brightness. To select MTL, a 20mm square-shaped Region of Interest is used. The correlation coefficient r =0.69 was achieved between two independent, non-experienced observers. Between two non-experienced observers the error of 27.95 % was achieved and between the measurements from the same observer the error was only 11.2 %. Meanwhile, the variance and the range were computed, both almost equal. These results have been judged by an experienced sonographer. In the future, the ratio could be an usable value to determine the MTL atrophy risk using the ratio value and possibility to create a rule-based expert system as a software tool to evaluate probability of Alzheimer's Disease using transcranial sonography.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    21100 - Other engineering and technologies

Result continuities

  • Project

  • Continuities

    N - Vyzkumna aktivita podporovana z neverejnych zdroju

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the International Conference on Biomedical Innovations and Applications, BIA 2020

  • ISBN

    9781728170732

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    53-57

  • Publisher name

    Technical University - Varna

  • Place of publication

    Bulharsko

  • Event location

    Bulharsko

  • Event date

    Jan 1, 2020

  • Type of event by nationality

    CST - Celostátní akce

  • UT code for WoS article