Digital Method of Automated Non-destructive Diagnostics for High-power Magnetron Resonator Blocks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F44555601%3A13440%2F22%3A43897180" target="_blank" >RIV/44555601:13440/22:43897180 - isvavai.cz</a>
Result on the web
<a href="https://www.mecs-press.org/ijigsp/ijigsp-v14-n1/IJIGSP-V14-N1-4.pdf" target="_blank" >https://www.mecs-press.org/ijigsp/ijigsp-v14-n1/IJIGSP-V14-N1-4.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5815/ijigsp.2022.01.04" target="_blank" >10.5815/ijigsp.2022.01.04</a>
Alternative languages
Result language
angličtina
Original language name
Digital Method of Automated Non-destructive Diagnostics for High-power Magnetron Resonator Blocks
Original language description
The paper reveals the problem of the lack of standard non-destructive diagnostic methods for high-power microwave devices aimed at regeneration. The issue is understudied and requires further research. The conducted analysis of state of the art on the subject area exhibited that image processing was used to specify the examined object's target characteristics in a wide range of research. Having summarized the considered image comparison methods on the subject area of this work, the authors formulated several requirements for the selected image analysis method based on the automated non-destructive diagnosis of resonator units for high-power magnetrons. The primary requirement is using non-iterative algorithms; the second condition is a chosen method of image analysis, and the third option is the number of pixels for a processed image. It must significantly exceed the number of descriptors required for making a decision. Guided by the analysis results and based on the results of previous studies conducted by the authors, the algorithm for identifying a defect in the resonator unit of a microwave device based on the image of the frequency-azimuthal distribution for the probing field phase difference expressed by the Zernike moments is proposed. MATLAB R14a was used as a modeling environment. The descriptor vector was restricted to the Zernike moments, including the 7th order. The work is interdisciplinary and written at the intersection of technical diagnostics, microwave engineering, and digital image processing.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20205 - Automation and control systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
International Journal of Image, Graphics and Signal Processing(IJIGSP)
ISSN
2074-9074
e-ISSN
2074-9082
Volume of the periodical
2022
Issue of the periodical within the volume
Vol. 14, Issue 1
Country of publishing house
HK - HONG KONG
Number of pages
10
Pages from-to
40-49
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85125236902