The effect of the window temperature on the thermal comfort in a room heated by a floor convector

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24210%2F14%3A00000343" target="_blank" >RIV/46747885:24210/14:00000343 - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    The effect of the window temperature on the thermal comfort in a room heated by a floor convector

  • Original language description

    The objective of this paper is the prediction of the surface temperature at a window with a prescribed heat flux, and how it affect the thermal comfort conditions in the space. The negative heat flux here represents the heat loss through a window. The temperature distribution at the window surface is a result of the interaction between a hot air jet and the cooled window surface. The temperature field at the window was determined by measurements using an infrared camera. The measurements were compared with CFD results. The k-epsilon RNG and k-omega turbulence modes were used for CFD simulation to classify the sensitivity of the temperature distribution on the turbulence model and the heat loss magnitude. Two directions and velocities of the hot air flux are compared. The calculation based on the k-omega turbulence model provided constant temperature distribution for wide range of heat fluxes. Results of the k-epsilon RNG model revealed the amount of influence of the intensity of the hot air jet.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/TA01020231" target="_blank" >TA01020231: An applied research concerned on the increase of the thermal efficiency of the heat exchanger and confirmation of the service conditions in relation to the renewable energy sources.</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate

  • ISBN

    978-1-63439-731-5

  • ISSN

  • e-ISSN

  • Number of pages

    9

  • Pages from-to

    494-502

  • Publisher name

    International Society of Indoor Air Quality and Climate

  • Place of publication

    Hong Kong

  • Event location

    Hong Kong

  • Event date

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article