All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Low-Temperature, Highly Sensitive Ammonia Sensors Based on Nanostructured Copper Iodide Layers

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F25%3A00012964" target="_blank" >RIV/46747885:24620/25:00012964 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/chemosensors13020029" target="_blank" >https://doi.org/10.3390/chemosensors13020029</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/chemosensors13020029" target="_blank" >10.3390/chemosensors13020029</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Low-Temperature, Highly Sensitive Ammonia Sensors Based on Nanostructured Copper Iodide Layers

  • Original language description

    Chemiresistive ammonia gas sensors with a low limit of detection of 0.15 ppm and moisture-independent characteristics based on p-type copper iodide (CuI) semiconductor films have been developed. CuI films were deposited on glass and polyethylene terephthalate (PET) substrates using a Successive Ionic Layer Adsorption and Reaction method to fabricate CuI/glass and CuI/PET gas sensors, respectively. They have a nanoscale morphology, an excess iodine and sulfur impurity content, a zinc blende γ-CuI crystal structure with a grain size of ~34 nm and an optical band gap of about 2.95 eV. The high selective sensitivity of both sensors to NH3 is explained by the formation of the [Cu(NH3)2]+ complex. At 5 °C, the responses to 3 ppm ammonia in air in terms of the relative resistance change were 24.5 for the CuI/glass gas sensor and 28 for the CuI/PET gas sensor, with short response times of 50 s to 210 s and recovery times of 10–70 s. The sensors have a fast response–recovery and their performance was well maintained after long-term stability testing for 45 days. After 1000 repeated bends of the flexible CuI/PET gas sensor in different directions, with bending angles up to 180° and curvature radii up to 0.25 cm, the response changes were only 3%.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Chemosensors>

  • ISSN

    2227-9040

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    21

  • Pages from-to

  • UT code for WoS article

    001432491600001

  • EID of the result in the Scopus database

    2-s2.0-85218467464