All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Sulfur-Doped Nanostructured Copper Iodide Films for Chemiresistive Ammonia Sensors Analyzing Exhaled Breath

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F46747885%3A24620%2F25%3A00013486" target="_blank" >RIV/46747885:24620/25:00013486 - isvavai.cz</a>

  • Result on the web

    <a href="https://onlinelibrary.wiley.com/doi/10.1002/pssa.202400966" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/pssa.202400966</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/pssa.202400966" target="_blank" >10.1002/pssa.202400966</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Sulfur-Doped Nanostructured Copper Iodide Films for Chemiresistive Ammonia Sensors Analyzing Exhaled Breath

  • Original language description

    Chemiresistive room-temperature sensors based on sulfur-doped copper iodide films have been developed and tested, which are suitable for the selective detection of ammonia (NH 3 ) in exhaled air for the purpose of disease diagnosis and monitoring. The films are deposited on glass and flexible polyethylene substrates and have a morphology of nanoflakes or triangular nanograins containing from 2 to 8 at% S depending on the mode of the automatic successive ionic layer adsorption and reaction method. The interfering effect of water vapor, acetone, and ethanol on the response of the ammonia sensors is insignificant due to the specific chemical interaction of copper iodide with ammonia. The high conductivity of the films allows the sensors to produce significant signals above noise-limited detection levels even at sub-ppm NH 3 concentrations. The detection limit of the developed sensors ≈0.15 ppm NH 3 is two times lower than the typical level of ammonia in the exhaled breath of a healthy person. The ammonia responses and response/recovery times are among the best chemiresistive sensors operating at room temperature. Using a low 1 V bias voltage for room temperature operation allows the sensors to be integrated with smartphones, giving them autonomy

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20500 - Materials engineering

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Physica Status Solidi (a)>

  • ISSN

    1862-6300

  • e-ISSN

  • Volume of the periodical

    222

  • Issue of the periodical within the volume

    19

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    19

  • Pages from-to

  • UT code for WoS article

    001463446600001

  • EID of the result in the Scopus database

    2-s2.0-105002254115