Calibration of nozzle for air mass flow measurement
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23210%2F17%3A43932955" target="_blank" >RIV/49777513:23210/17:43932955 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1063/1.5004379" target="_blank" >http://dx.doi.org/10.1063/1.5004379</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5004379" target="_blank" >10.1063/1.5004379</a>
Alternative languages
Result language
angličtina
Original language name
Calibration of nozzle for air mass flow measurement
Original language description
The effort to make calibration measurement of mass flow through a nozzle was not satisfying. Traversing across the pipe radius with Pitot probe was done. The presence of overshoot behind the bend in the pipe was found. The overshoot led to an asymmetric velocity profile.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20302 - Applied mechanics
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
AIP Conference Proceedings
ISBN
978-0-7354-1572-0
ISSN
0094-243X
e-ISSN
neuvedeno
Number of pages
6
Pages from-to
020045-1 - 020045-6
Publisher name
AIP Publishing
Place of publication
Melville
Event location
Plzeň
Event date
Jun 13, 2017
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
000417391000045