Original language description
The paper deals with a model-based approach to fault detection in the framework of electromagnetic actuator in valve operation and with its experimental validation. The forward uncertainty propagation for the mathematical model of the actuator is tested to determine probability of faultless operation under aleatoric and epistemic uncertainties. Afterwards, the six sigma approach is used by the control algorithm to make decision on occurred fault, which is identified by measurement of induced voltage in the field coils during actuator operation.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LO1607" target="_blank" >LO1607: RICE - New technologies and concepts for smart industrial system</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů