The influence of the cold crucible construction parts on its own power losses

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F17%3A43932194" target="_blank" >RIV/49777513:23220/17:43932194 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.elektrorevue.cz/cz/clanky/analogova-technika--vzajemny-a-d-prevod/0/the-influence-of-the-cold-crucible-construction-parts-on-its-own-power-losses/" target="_blank" >http://www.elektrorevue.cz/cz/clanky/analogova-technika--vzajemny-a-d-prevod/0/the-influence-of-the-cold-crucible-construction-parts-on-its-own-power-losses/</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    The influence of the cold crucible construction parts on its own power losses

  • Original language description

    This article is focused on the influence of the cold crucible (CC) construction parts on its own power losses. The influence of construction parts was verified by numerical simulation by ANSYS EM (AM) and by measuring on own system based on Compact RIO (National Instruments). The study considers three variants: separate tubes, connected two tubes, bottom and bandage. For greater complexity, passive parameters for each arrangement were measured and calculated. The motivation to create this study was need to produce own segmented cold crucibles with lower power losses. Thanks to 3D printing, we were able to create real samples that allowed us to consider the individual parts of the cold crucible separately. The scientific articles and available literature solve this problem only marginally. The results of our measurements and simulations have shown that the most important influence (on the distribution of power losses) has the electric conductive bottom and bandage.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>ost</sub> - Miscellaneous article in a specialist periodical

  • CEP classification

  • OECD FORD branch

    20704 - Energy and fuels

Result continuities

  • Project

    <a href="/en/project/ED2.1.00%2F03.0108" target="_blank" >ED2.1.00/03.0108: Sustainable Energy</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Elektrorevue

  • ISSN

    1213-1539

  • e-ISSN

  • Volume of the periodical

    19

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    7

  • Pages from-to

    84-90

  • UT code for WoS article

  • EID of the result in the Scopus database