Photovoltaic generators as power regulate sources in electrical networks
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F17%3A43949940" target="_blank" >RIV/49777513:23220/17:43949940 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Photovoltaic generators as power regulate sources in electrical networks
Original language description
With the increasing number of distributed generators which transform renewable power sources to electricity, PV generators trough invertors, when is usually difficult to make power output regulation from the primary source side, is the problem of the output power adapting according to the consumption requirements increasingly important. Therefore, it will be necessary to involve these sources to the transmitted power regulation in the electricity supply system. If these resources are designed to operate in island mode, the regulation of them is directly necessary. Control of the three-phase voltage inverts is fundamentally the same as the control of synchronous generators, which allows managing voltage and frequency and inject into the network power values which correspond to a the actual change of the load. In the distribution systems usually as frequency as voltage are influenced by active power as well as reactive power. The share of the individual performance is determined by the impedance ratio (R/X) in the given part of network. Therefore, instead of the traditional characteristics, there are used so called the virtual methods. The paper deals with the frequency regulation possibilities of PV generators by primary frequency and secondary control, using the virtual power method during the microgrid island mode. These possibilities are presented by model examples in MATLAB, Simulink software. Simulation results showed that the frequency and voltage values stayed during any load changes in the limit range due to primary control. The activation of the secondary control will restore their nominal values and there is possible to use this method for PV generator regulation.
Czech name
—
Czech description
—
Classification
Type
C - Chapter in a specialist book
CEP classification
—
OECD FORD branch
20704 - Energy and fuels
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Book/collection name
Electric Power Engineering and Ecology - Selected Parts VI.
ISBN
978-80-7300-551-1
Number of pages of the result
12
Pages from-to
76-87
Number of pages of the book
95
Publisher name
BEN - odborná literatura
Place of publication
Praha
UT code for WoS chapter
—