Dielectric behaviour of gaseous insulation with synthetic air

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F18%3A43951364" target="_blank" >RIV/49777513:23220/18:43951364 - isvavai.cz</a>

  • Result on the web

    <a href="https://ieeexplore.ieee.org/document/8396010" target="_blank" >https://ieeexplore.ieee.org/document/8396010</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EPE.2018.8396010" target="_blank" >10.1109/EPE.2018.8396010</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dielectric behaviour of gaseous insulation with synthetic air

  • Original language description

    The latest research results presented in this paper deals with performance of synthetic air gaseous insulation near the limiting homogeneity. In previous published research [1] numerous tests have been performed to describe the dielectric behavior of strong inhomogeneous arrangements at various gas pressures. Besides that it was of interest if the obtained trends are valid even at higher values of gas pressure, therefore, further investigations were made and results obtained for observed pressures and distances at different level of field homogeneity together with streamer criterion based calculation results are published here. The research had two main targets, breakdown behavior at AC test voltage and breakdown behavior at lightning impulse test voltage. The breakdown behavior at lightning impulse stress shows a certain polarity effect. In opposition to the behavior of SF6 the lowest breakdown values occur at positive polarity of the applied test voltage. The gas pressure was in the range from 0.1 to 0.3 MPa and the electrode distance was in the range from 1 to 9 cm. Used electrode testing configuaration was “tip - bowl”. Variously selected test parameters provide different field inhomogeneity (field type).

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

  • OECD FORD branch

    20201 - Electrical and electronic engineering

Result continuities

  • Project

    <a href="/en/project/LO1607" target="_blank" >LO1607: RICE - New technologies and concepts for smart industrial system</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2018

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 2018 19th International Scientific Conference on Electric Power Engineering (EPE)

  • ISBN

    978-1-5386-4612-0

  • ISSN

    2376-5623

  • e-ISSN

    2376-5631

  • Number of pages

    4

  • Pages from-to

    367-370

  • Publisher name

    IEEE

  • Place of publication

    Piscataway

  • Event location

    Brno, Česká republika

  • Event date

    May 16, 2018

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000439649500069