All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Dielectric behaviour of gaseous insulation with synthetic air at AC stress

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F49777513%3A23220%2F16%3A43928869" target="_blank" >RIV/49777513:23220/16:43928869 - isvavai.cz</a>

  • Result on the web

    <a href="http://ieeexplore.ieee.org/document/7521740/" target="_blank" >http://ieeexplore.ieee.org/document/7521740/</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1109/EPE.2016.7521740" target="_blank" >10.1109/EPE.2016.7521740</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Dielectric behaviour of gaseous insulation with synthetic air at AC stress

  • Original language description

    The paper deals with basic investigation of AC breakdown behaviour of gaseous insulation with synthetic air at different level of field homogeneity and gas pressure. The measurement was performed at different gas pressure ranging from 0.1 to 0.25 MPa and gap distances from 1 to 9 cm, using an electrode test-set "tip - bowl". The test parameters were chosen in such a way that different field types could be realized. At small distances the electrical field is weakly inhomogeneous and the breakdown values correspond to the discharge inception level. The measured values show a reasonable agreement to those values based on the calculation of the streamer criterion by using a relevant approximation formula for the effective ionisation coefficient. For larger distances the electrical field becomes more inhomogeneous and the calculated streamer inception voltage corresponds to the partial discharge (PD) inception voltage only. The calculated inception voltage values fit the measured values over the applied gap distance and gas pressure quite sufficiently. The best fit to the measured results was reached by slightly changing the parameters of the approximation formula depending on the gas pressure value. Additional PD measurement shows different PD activity dependent on gas pressure and gap distance.

  • Czech name

  • Czech description

Classification

  • Type

    D - Article in proceedings

  • CEP classification

    JA - Electronics and optoelectronics

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/LO1607" target="_blank" >LO1607: RICE - New technologies and concepts for smart industrial system</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Article name in the collection

    Proceedings of the 2016 17th International Scientific Conference on Electric Power Engineering (EPE)

  • ISBN

    978-1-5090-0907-7

  • ISSN

  • e-ISSN

  • Number of pages

    5

  • Pages from-to

    325-329

  • Publisher name

    Czech Technical University in Prague

  • Place of publication

    Prague

  • Event location

    Praha, Česká republika

  • Event date

    May 16, 2016

  • Type of event by nationality

    WRD - Celosvětová akce

  • UT code for WoS article

    000382934600026