The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60076658%3A12410%2F24%3A43909748" target="_blank" >RIV/60076658:12410/24:43909748 - isvavai.cz</a>
Result on the web
<a href="https://www.minervamedica.it/en/journals/minerva-respiratory-medicine/article.php?cod=R16Y2025N02A0056" target="_blank" >https://www.minervamedica.it/en/journals/minerva-respiratory-medicine/article.php?cod=R16Y2025N02A0056</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.23736/S2784-8477.25.02191-6" target="_blank" >10.23736/S2784-8477.25.02191-6</a>
Alternative languages
Result language
angličtina
Original language name
The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial
Original language description
BACKGROUND: Facemasks are increasingly widespread after the COVID-19 pandemic. However, there are some concerns regarding potentially harmful effects on respiration. The purpose of this study was to compare breathing patterns and the contribution of individual breathing compartments (IBC) with and without filtering facepiece respirator (FFR) during exercise. METHODS: Twenty-one healthy, well-trained participants (10 female) were randomly selected to complete either a test with FFR or without on the first day, followed by the alternative two days apart. Each day of testing consisted of a graded Bruce protocol on a treadmill (GXT). Three IBC were considered and measured using optoelectronic plethysmography (OEP) during four stages of GXT: pulmonary rib cage (VRCp), abdominal rib cage (VRCa), abdomen (VAb). Concurrently, inspiratory time (Ti), expiratory time (TE) and respiratory frequency (fR) were collected. RESULTS: Despite a substantial increase in inspiratory mean time during GXT stage 2 (13.2%, d=0.41), stage 3 (10.7%, d=0.41), and stage 4 (11.5%, d=0.67) while wearing FFR, the relative contributions of IBCs did not differ between conditions. CONCLUSIONS: This suggests that the increased work of breathing due to the respirator resistance is evenly distributed among the IBCs. While there may be negligible acute effects of FFR on breathing in well-trained individuals, long-term effects may differ. (Cite this article as: Marko D, Harbour E, Bahensk & yacute; P, Krajcigr M, Mal & aacute;tov & aacute; R, Mal & yacute; T, et al. The filtering facepiece respirator increases inspiratory time, but does not change the contribution of breathing compartments during exercise: a randomized trial. Minerva Respir Med 2025;64:56-63. DOI: 10.23736/S2784-8477.25.02191-6)
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30203 - Respiratory systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Minerva Respiratory Medicine
ISSN
2784-8477
e-ISSN
2724-6493
Volume of the periodical
64
Issue of the periodical within the volume
2
Country of publishing house
IT - ITALY
Number of pages
8
Pages from-to
56-63
UT code for WoS article
001529087800002
EID of the result in the Scopus database
—