Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F16%3A43875673" target="_blank" >RIV/60162694:G44__/16:43875673 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.nel.edu/Current_issue_0.htm" target="_blank" >http://www.nel.edu/Current_issue_0.htm</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap

  • Original language description

    OBJECTIVES: Glucose is an important diagnostic biochemical marker of diabetes but also for organophosphates, carbamates, acetaminophens or salicylates poisoning. Hence, innovation of accurate and fast detection assay is still one of priorities in biomedical research. METHODS: Glucose sensor based on magnetic particles (MPs) with immobilized enzymes glucose oxidase (GOx) and horseradish peroxidase (HRP) was developed and the GOx catalyzed reaction was visualized by a smart-phone-integrated camera. RESULTS: Exponential decay concentration curve with correlation coefficient 0.997 and with limit of detection 0.4 mmol/l was achieved. Interfering and matrix substances were measured due to possibility of assay influencing and no effect of the tested substances was observed. Spiked plasma samples were also measured and no influence of plasma matrix on the assay was proved. CONCLUSIONS: The presented assay showed complying results with reference method (standard spectrophotometry based on enzymes glucose oxidase and peroxidase inside plastic cuvettes) with linear dependence and correlation coefficient 0.999 in concentration range between 0 and 4 mmol/l. On the grounds of measured results, method was considered as highly specific, accurate and fast assay for detection of glucose.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Neuroendocrinology Letters

  • ISSN

    0172-780X

  • e-ISSN

  • Volume of the periodical

    37

  • Issue of the periodical within the volume

    Suppl. 1

  • Country of publishing house

    SE - SWEDEN

  • Number of pages

    7

  • Pages from-to

    132-138

  • UT code for WoS article

    000406112100020

  • EID of the result in the Scopus database

    2-s2.0-85018820388