Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F16%3A43875673" target="_blank" >RIV/60162694:G44__/16:43875673 - isvavai.cz</a>
Result on the web
<a href="http://www.nel.edu/Current_issue_0.htm" target="_blank" >http://www.nel.edu/Current_issue_0.htm</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Phone camera detection of glucose blood level based on magnetic particles entrapped inside bubble wrap
Original language description
OBJECTIVES: Glucose is an important diagnostic biochemical marker of diabetes but also for organophosphates, carbamates, acetaminophens or salicylates poisoning. Hence, innovation of accurate and fast detection assay is still one of priorities in biomedical research. METHODS: Glucose sensor based on magnetic particles (MPs) with immobilized enzymes glucose oxidase (GOx) and horseradish peroxidase (HRP) was developed and the GOx catalyzed reaction was visualized by a smart-phone-integrated camera. RESULTS: Exponential decay concentration curve with correlation coefficient 0.997 and with limit of detection 0.4 mmol/l was achieved. Interfering and matrix substances were measured due to possibility of assay influencing and no effect of the tested substances was observed. Spiked plasma samples were also measured and no influence of plasma matrix on the assay was proved. CONCLUSIONS: The presented assay showed complying results with reference method (standard spectrophotometry based on enzymes glucose oxidase and peroxidase inside plastic cuvettes) with linear dependence and correlation coefficient 0.999 in concentration range between 0 and 4 mmol/l. On the grounds of measured results, method was considered as highly specific, accurate and fast assay for detection of glucose.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Neuroendocrinology Letters
ISSN
0172-780X
e-ISSN
—
Volume of the periodical
37
Issue of the periodical within the volume
Suppl. 1
Country of publishing house
SE - SWEDEN
Number of pages
7
Pages from-to
132-138
UT code for WoS article
000406112100020
EID of the result in the Scopus database
2-s2.0-85018820388