Sensitivity and kinetics of an NS1-based Zika virus enzyme-linked immunosorbent assay in Zika virus-infected travelers from Israel, the Czech Republic, Italy, Belgium, Germany, and Chile
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60162694%3AG44__%2F17%3A43875760" target="_blank" >RIV/60162694:G44__/17:43875760 - isvavai.cz</a>
Alternative codes found
RIV/71009396:_____/17:N0000016
Result on the web
<a href="http://jcm.asm.org/content/55/6/1894" target="_blank" >http://jcm.asm.org/content/55/6/1894</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1128/JCM.00346-17" target="_blank" >10.1128/JCM.00346-17</a>
Alternative languages
Result language
angličtina
Original language name
Sensitivity and kinetics of an NS1-based Zika virus enzyme-linked immunosorbent assay in Zika virus-infected travelers from Israel, the Czech Republic, Italy, Belgium, Germany, and Chile
Original language description
Serological diagnosis of Zika virus is challenging due to high cross-reactivity of Zika virus with other flavivirus antibodies. Recently, a Zika NS1-based enzyme-linked immunosorbent assay (ELISA) was developed and shown to be highly specific for Zika antibody detection; however, sensitivity was evaluated for only a small number of confirmed Zika-infected patients. In this study, we measured the sensitivity and kinetics of Zika IgM and IgG antibodies using the Zika NS1-based ELISA in 105 samples from 63 returning travelers infected with Zika virus (proven by PCR or neutralization assay) from Israel, Czech Republic, Italy, Belgium, Germany, and Chile. Zika virus IgM was detected from 2 to 42 days post-symptom onset (PSO) with an overall sensitivity of 79% in the first month and 68% until 2 months PSO, while IgG antibodies were detected from 5 days to 3 years PSO with 79% sensitivity. Interestingly, significant differences in IgM sensitivity and IgM detection period were observed between Israeli and European/Chilean Zika-infected travelers, adding to the complexity of Zika infection diagnosis and suggesting that other diagnostic methods should be complemented to reduce false-negative results.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10606 - Microbiology
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Clinical Microbiology
ISSN
0095-1137
e-ISSN
—
Volume of the periodical
55
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
1894-1901
UT code for WoS article
000405336200033
EID of the result in the Scopus database