All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Enantioseparation and Determination of Mephedrone and Its Metabolites by Capillary Electrophoresis Using Cyclodextrins as Chiral Selectors

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22310%2F20%3A43920230" target="_blank" >RIV/60461373:22310/20:43920230 - isvavai.cz</a>

  • Alternative codes found

    RIV/60461373:22330/20:43920230 RIV/60461373:22340/20:43920230 RIV/60461373:22810/20:43920230

  • Result on the web

    <a href="https://www.mdpi.com/1420-3049/25/12/2879" target="_blank" >https://www.mdpi.com/1420-3049/25/12/2879</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/molecules25122879" target="_blank" >10.3390/molecules25122879</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Enantioseparation and Determination of Mephedrone and Its Metabolites by Capillary Electrophoresis Using Cyclodextrins as Chiral Selectors

  • Original language description

    Mephedrone, a psychoactive compound derived from cathinone, is widely used as a designer drug. The determination of mephedrone and its metabolites is important for understanding its possible use in medicine. In this work, a method of capillary electrophoresis for the chiral separation of mephedrone and its metabolites was developed. Carboxymethylated -cyclodextrin was selected as the most e ective chiral selector from seven tested cyclodextrin derivates. Based on the simplex method, the optimal composition of the background electrolyte was determined: at pH 2.75 and 7.5 mmolL????1 carboxymethylated -cyclodextrin the highest total resolution of a mixture of analytes was achieved. For mephedrone and its metabolites, calibration curves were constructed in a calibration range from 0.2 to 5 mmolL????1; limits of detection, limits of quantification, precision, and repeatability were calculated, and according to Mandel’s fitting test, the linear calibration ranges were determined.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/VI20172020056" target="_blank" >VI20172020056: New synthetics drugs - complex interdisciplinary research centre</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Molecules

  • ISSN

    1420-3049

  • e-ISSN

  • Volume of the periodical

    25

  • Issue of the periodical within the volume

    12

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    12

  • Pages from-to

    2879-2880

  • UT code for WoS article

    000553984300001

  • EID of the result in the Scopus database

    2-s2.0-85087141675