Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F12%3A43894800" target="_blank" >RIV/60461373:22330/12:43894800 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1002/rcm.6466" target="_blank" >http://dx.doi.org/10.1002/rcm.6466</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/rcm.6466" target="_blank" >10.1002/rcm.6466</a>
Alternative languages
Result language
angličtina
Original language name
Direct analysis in real time high-resolution mass spectrometry for high-throughput analysis of antiparasitic veterinary drugs in feed and food
Original language description
RATIONALE: Direct analysis in real time (DART) is a novel ionization technique that has been demonstrated in numerous applications as a useful tool for fast and convenient mass spectrometry (MS)-based analysis of complex samples. In this study, the feasibility of DART ionization coupled to a high-resolution mass spectrometer utilizing an orbitrap mass analyzer (orbitrap MS) for high-throughput analysis of antiparasitic veterinary drugs was explored. METHODS: To obtain the best DART-orbitrap MS performance, stepwise optimization of instrumental parameter settings, such as ionization gas temperature and mass resolving power, was performed. The optimized method was applied to feed and bovine milk samples previously extracted following a QuEChERS-like strategy. RESULTS: Most antiparasitic drugs could be analyzed following the described method. Positive DART ionization provided the protonated molecules [M+H](+) ; in negative DART ion mode, deprotonated molecules [M-H](-) were observed. As a
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
GM - Food industry
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Rapid Communications in Mass Spectrometry
ISSN
0951-4198
e-ISSN
—
Volume of the periodical
27
Issue of the periodical within the volume
3
Country of publishing house
GB - UNITED KINGDOM
Number of pages
9
Pages from-to
467-475
UT code for WoS article
000312888100011
EID of the result in the Scopus database
—