Interlaboratory Comparison Investigations (ICIs) for human biomonitoring of chromium as part of the quality assurance programme under HBM4EU
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22330%2F22%3A43925050" target="_blank" >RIV/60461373:22330/22:43925050 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.jtemb.2021.126912" target="_blank" >https://doi.org/10.1016/j.jtemb.2021.126912</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jtemb.2021.126912" target="_blank" >10.1016/j.jtemb.2021.126912</a>
Alternative languages
Result language
angličtina
Original language name
Interlaboratory Comparison Investigations (ICIs) for human biomonitoring of chromium as part of the quality assurance programme under HBM4EU
Original language description
Background: The pan-European human biomonitoring initiative HBM4EU targets the harmonization of human biomonitoring (HBM) procedures and data for both environmental and occupational exposure, including chromium. The determination of chromium in urine (U-Cr), plasma (P-Cr) and whole blood (WB-Cr) is a common HBM application in employees occupationally exposed to chromium (VI) compounds. Methods: European laboratories which have registered as candidate laboratories for chromium analysis within HBM4EU were invited to participate in a quality assurance/qualitycontrol (QA/QC) programme comprising interlaboratory comparison investigations (ICI) for the parameters U-Cr, P-Cr and WB-Cr. Participating laboratories received two samples of different concentrations in each of four rounds and were asked to analyse the samples using their standard analytical procedure. The data were evaluated by the Z-score approach and were reported to the participants after each round. Results: The majority of the 29 participating laboratories obtained satisfactory results, although low limits of quantification were required to quantify chromium concentrations in some of the ICI materials. The robust relative standard deviation of the participants’ results (study RSDR) obtained from all ICI runs ranged from 6 to 16 % for U-Cr, 7–18 % for P-Cr and 4–47 % for WB-Cr. The application of both inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (EAAS) appeared appropriate for the determination of chromium in urine, plasma and whole blood with regard to occupational exposure levels. Conclusion: This QA/QC programme succeeded in establishing a network of laboratories with high analytical comparability and accuracy for the analysis of chromium across Europe. © 2021 Elsevier GmbH
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
R - Projekt Ramcoveho programu EK
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Trace Elements in Medicine and Biology
ISSN
0946-672X
e-ISSN
1878-3252
Volume of the periodical
70
Issue of the periodical within the volume
MAR 2022
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
8
Pages from-to
nestrankovano
UT code for WoS article
000777738300007
EID of the result in the Scopus database
2-s2.0-85121607679