All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

High-throughput nucleoside phosphate monitoring in mammalian cell fed-batch cultivation using quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60461373%3A22340%2F15%3A43900198" target="_blank" >RIV/60461373:22340/15:43900198 - isvavai.cz</a>

  • Result on the web

    <a href="http://onlinelibrary.wiley.com/doi/10.1002/biot.201400292/abstract" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/biot.201400292/abstract</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/biot.201400292" target="_blank" >10.1002/biot.201400292</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    High-throughput nucleoside phosphate monitoring in mammalian cell fed-batch cultivation using quantitative matrix-assisted laser desorption/ionization time-of-flight mass spectrometry

  • Original language description

    Current methods for monitoring multiple intracellular metabolite levels in parallel are limited in sample throughput capabilities and analyte selectivity. This article presents a novel high-throughput method based on matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry (TOF-MS) for monitoring intracellular metabolite levels in fed-batch processes. The MALDI-TOF-MS method presented here is based on a new microarray sample target and allows the detection of nucleoside phosphates and various other metabolites using stable isotope labeled internal standards. With short sample preparation steps and thus high sample throughput capabilities, the method is suitable for monitoring mammalian cell cultures, such as antibody producing hybridoma cell lines in industrial environments. The method is capable of reducing the runtime of standard LC-UV methods to approximately 1 min per sample (including 10 technical replicates). Its performance is exemplarily demonstrated

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CI - Industrial chemistry and chemical engineering

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Biotechnology Journal

  • ISSN

    1860-7314

  • e-ISSN

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    9

  • Pages from-to

    190-198

  • UT code for WoS article

    000348058200022

  • EID of the result in the Scopus database