UTILIZATION OF OPERATIONAL PARAMETERS MONITORING TO ECONOMICAL AND SAFETY DRIVE OF VEHICLES
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F60489626%3A_____%2F21%3AN0000004" target="_blank" >RIV/60489626:_____/21:N0000004 - isvavai.cz</a>
Result on the web
<a href="https://www.mmscience.eu/journal/issues/march-2022/articles/utilization-of-operational-parameters-monitoring-to-economical-and-safety-drive-of-vehicles" target="_blank" >https://www.mmscience.eu/journal/issues/march-2022/articles/utilization-of-operational-parameters-monitoring-to-economical-and-safety-drive-of-vehicles</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.17973/MMSJ.2022_03_2021190" target="_blank" >10.17973/MMSJ.2022_03_2021190</a>
Alternative languages
Result language
angličtina
Original language name
UTILIZATION OF OPERATIONAL PARAMETERS MONITORING TO ECONOMICAL AND SAFETY DRIVE OF VEHICLES
Original language description
The paper is focused on the issue of measuring the amount of fuel in the tank of truck, construction and agriculture machine. The gradual expansion of of the share of the biocomponent in diesel fuel results in greater measurement errors via the capacitive probe in the fuel tank. The proposed solution, which uses three electrodes leads to increased accuracy in measuring of the amount of fuel in the tank. According to standard EN 590, the measurement error of the new capacitive probe is only 1.5% when using diesel. The highest measurement error 4% is achieved when using neat rapeseed oil methyl ester. The previous solution of the capacitive probe when using diesel fuel according to EN 590 achieved a measurement error of 2.5%, but it increased significantly with the proportion of rapeseed oil methyl ester up to 70% when using neat rapeseed oil methyl ester. The new capacitive probe concept with two positive electrodes and higher accuracy can be used to evaluate driving style towards economical and environmentally friendly driving. It is also possible to focus on safe driving style of drivers using other operating parameters. The aim of the paper is to compare the capacitive probe with one and two positive electrodes and demonstrate their use in evaluating the driving style of drivers.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/FV40214" target="_blank" >FV40214: Reducing the energy intensity of transport by innovation the telematics system and introducing of evaluation driving style</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
MM SCIENCE JOURNAL
ISSN
1803-1269
e-ISSN
1805-0476
Volume of the periodical
2022
Issue of the periodical within the volume
March
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
7
Pages from-to
5582 – 5588
UT code for WoS article
000767288700001
EID of the result in the Scopus database
2-s2.0-85126547240