All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F25%3A00598227" target="_blank" >RIV/61388955:_____/25:00598227 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216275:25310/25:39921672

  • Result on the web

    <a href="https://www.sciencedirect.com/science/article/pii/S0039914024011883?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914024011883?via%3Dihub</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2024.126809" target="_blank" >10.1016/j.talanta.2024.126809</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

  • Original language description

    New voltammetric and flow amperometric methods for the determination of guaifenesin (GFE) using a perspective screen-printed sensor (SPE) with boron-doped diamond electrode (BDDE) were developed. The electrochemical oxidation of GFE was studied on the surface of the oxygen-terminated BDDE of the sensor. The GFE provided two irreversible anodic signals at a potential of 1.0 and 1.1 V (vs. Ag|AgCl|KCl sat.) in Britton-Robinson buffer (pH 2), which was chosen as the supporting electrolyte for all measurements. First, a voltammetric method based on differential pulse voltammetry was developed and a low detection limit (LOD = 41 nmol L−1), a wide linear dynamic range (LDR = 0.1–155 μmol L−1), and a good recovery in the analysis of model and pharmaceutical samples (RSD <3.0 %) were obtained. In addition, this sensor demonstrated excellent sensitivity and reproducibility in the analysis of biological samples (RSD <3.2 %), where the analysis took place in a drop of serum (50 μL) without pretreatment and additional electrolyte. Subsequently, SP/BDDE was incorporated into a flow-through 3D printed electrochemical cell and a flow injection analysis method with electrochemical detection (FIA-ED) was developed, resulting in excellent analytical parameters (LOD = 86 nmol L−1, LDR = 0.1–50 μmol L−1). Moreover, the mechanism of electrochemical oxidation of GFE was proposed based on calculations of HOMO spatial distribution and spectroelectrochemical measurements focused on IR identification of intermediates and products.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10406 - Analytical chemistry

Result continuities

  • Project

    <a href="/en/project/EH22_008%2F0004558" target="_blank" >EH22_008/0004558: Advanced MUltiscaLe materials for key Enabling Technologies</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

    1873-3573

  • Volume of the periodical

    281

  • Issue of the periodical within the volume

    JAN 2025

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    10

  • Pages from-to

    126809

  • UT code for WoS article

    001316426300001

  • EID of the result in the Scopus database

    2-s2.0-85203636342