All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Voltammetric determination of lercanidipine in urine, blood plasma, and serum using hollow fiber-based liquid phase microextraction

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388955%3A_____%2F25%3A00618965" target="_blank" >RIV/61388955:_____/25:00618965 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216275:25310/25:39922804

  • Result on the web

    <a href="https://hdl.handle.net/11104/0365764" target="_blank" >https://hdl.handle.net/11104/0365764</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.talanta.2025.128038" target="_blank" >10.1016/j.talanta.2025.128038</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Voltammetric determination of lercanidipine in urine, blood plasma, and serum using hollow fiber-based liquid phase microextraction

  • Original language description

    This study investigates a synergistic combination of hollow fiber-based liquid phase microextraction (HF-LPME) and voltammetric analysis using screen-printed boron-doped diamond electrodes (SP-BDDE) for the determination of antihypertensive drug lercanidipine (LCN) in urine, blood plasma, and blood serum. Optimum HF-LPME conditions were: dodecane as supported liquid membrane, Britton-Robinson buffer (BRB) pH 7 as donor solution, BRB pH 3 as acceptor solution, and extraction time 30 min. Square-wave voltammetry (SWV) of 10 μL acceptor solution at SP-BDDE was utilized with amplitude 75 mV, frequency 10 Hz, and potential step 4 mV. The calibration dependence of the combined HF-LPME-SWV method was established in the range of 1–1000 nmol L−1, with limits of quantification (LOQ) and detection (LOD) of 3.3 and 1.1 nmol L−1, respectively. The applicability of the developed method was verified by analysis of human urine, blood plasma, and blood serum samples spiked with 20 and 100 nmol L−1 LCN with recoveries ranging from 93.2 to 112.9 % with respective RSDs 1.72–8.5 % (n = 3).

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10403 - Physical chemistry

Result continuities

  • Project

    <a href="/en/project/EH22_008%2F0004558" target="_blank" >EH22_008/0004558: Advanced MUltiscaLe materials for key Enabling Technologies</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2025

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Talanta

  • ISSN

    0039-9140

  • e-ISSN

    1873-3573

  • Volume of the periodical

    293

  • Issue of the periodical within the volume

    OCT 2025

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    9

  • Pages from-to

    128038

  • UT code for WoS article

    001468923600001

  • EID of the result in the Scopus database

    2-s2.0-105002007634