Detection and Quantification of Carbohydrate-Deficient Transferrin by MALDI-Compatible Protein Chips Prepared by Ambient Ion Soft Landing
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61388971%3A_____%2F18%3A00496286" target="_blank" >RIV/61388971:_____/18:00496286 - isvavai.cz</a>
Alternative codes found
RIV/00216208:11140/18:10378718 RIV/00216208:11310/18:10378718 RIV/00064173:_____/18:N0000012 RIV/00669806:_____/18:10378718
Result on the web
<a href="http://dx.doi.org/10.1373/clinchem.2017.285452" target="_blank" >http://dx.doi.org/10.1373/clinchem.2017.285452</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1373/clinchem.2017.285452" target="_blank" >10.1373/clinchem.2017.285452</a>
Alternative languages
Result language
angličtina
Original language name
Detection and Quantification of Carbohydrate-Deficient Transferrin by MALDI-Compatible Protein Chips Prepared by Ambient Ion Soft Landing
Original language description
BACKGROUND: Transferrin is synthetized in the liver and is the most important iron-transport carrier in the human body. Severe alcohol consumption leads to alterations in glycosylation of transferrin. Mass spectrometry can provide fast detection and quantification of transferrin isoforms because they have different molecular masses. In this study, we used antibody chips in combination with MALDI-TOF MS for the detection and quantification of transferrin isoforms. nMETHODS: Protein chips were prepared by functionalization of indium tin oxide glass using ambient ion soft landing of electrosprayed antitransferrin antibody. Two microliters of patient serum was applied on the antibody-modified spots, and after incubation, washing, and matrix deposition, transferrin isoforms were detected by MALDI-TOF MS. Peak intensities of each transferrin form were used to calculate total carbohydrate-deficient transferrin (CDT). The CDT values obtained by the MALDI chip method were compared with the results obtained by a standard capillary electrophoresis (CE). nRESULTS: The chip-based MALDI-TOF MS method was used for enrichment and detection of CDT from human serum. A sample cohort from 186 patients was analyzed. Of these samples, 44 were positively identified as belonging to alcoholic patients, whereas 142 were negative by the MALDI chip approach. The correlation of the data obtained by the CE and the chip-based MALDI was r = 0.986, 95% CI. nCONCLUSIONS: Functionalized MALDI chips modified by antitransferrin antibody prepared by ambient ion soft landing were successfully used for detection and quantification of CDT from human sera. (c) 2018 American Association for Clinical Chemistry.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10608 - Biochemistry and molecular biology
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Clinical Chemistry
ISSN
0009-9147
e-ISSN
—
Volume of the periodical
64
Issue of the periodical within the volume
9
Country of publishing house
US - UNITED STATES
Number of pages
8
Pages from-to
1319-1326
UT code for WoS article
000448300800011
EID of the result in the Scopus database
2-s2.0-85052469905