The characterization of PEEK, PET and PI implanted with Co ions to high fluences

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F13%3A00393346" target="_blank" >RIV/61389005:_____/13:00393346 - isvavai.cz</a>

  • Alternative codes found

    RIV/61389013:_____/13:00393346 RIV/60461373:22310/13:43896639 RIV/44555601:13440/13:43884983

  • Result on the web

    <a href="http://ac.els-cdn.com/S0169433212022222/1-s2.0-S0169433212022222-main.pdf?_tid=dbf9e606-df24-11e2-b873-00000aacb35d&acdnat=1372336197_4b4233224d734b70b85eb71d11862e0c" target="_blank" >http://ac.els-cdn.com/S0169433212022222/1-s2.0-S0169433212022222-main.pdf?_tid=dbf9e606-df24-11e2-b873-00000aacb35d&acdnat=1372336197_4b4233224d734b70b85eb71d11862e0c</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.apsusc.2012.12.071" target="_blank" >10.1016/j.apsusc.2012.12.071</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The characterization of PEEK, PET and PI implanted with Co ions to high fluences

  • Original language description

    Polyimide (PI), polyetheretherketone (PEEK), and polyethylene terephthalate (PET) foils have been implanted with 40 keV Co+ ions at room temperature to the fluences ranging from 0.2 x 10(16) cm(-2) to 1.0 x 10(17) cm(-2). Co depth profiles determined byRBS have been compared to SRIM 2008 calculations. The measured projected ranges RP differ slightly from the SRIM simulation because of the compositional changes in polymers implanted to high fluences; especially the widths of the Co profiles are much larger than those simulated by SRIM. Oxygen and hydrogen depletion has been examined using the RBS and ERDA techniques. The surface morphology of the implanted polymers has been characterized using AFM. The PET polymer exhibits lower oxygen escape than thePI and PEEK, but the surface roughness at PET has been affected most significantly after the implantation. Implanted Co atoms tend to aggregate into nanoparticles, the size and distribution of which has been determined from TEM micrograph

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Applied Surface Science

  • ISSN

    0169-4332

  • e-ISSN

  • Volume of the periodical

    275

  • Issue of the periodical within the volume

    JUN 15

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    5

  • Pages from-to

    311-315

  • UT code for WoS article

    000318977300050