All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Characterisation of PEEK, PET and PI implanted with 80 keV Fe+ ions to high fluencies

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F14%3A00433162" target="_blank" >RIV/61389005:_____/14:00433162 - isvavai.cz</a>

  • Alternative codes found

    RIV/60461373:22310/14:43898177 RIV/44555601:13440/14:43885850

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.nimb.2013.12.045" target="_blank" >http://dx.doi.org/10.1016/j.nimb.2013.12.045</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.nimb.2013.12.045" target="_blank" >10.1016/j.nimb.2013.12.045</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Characterisation of PEEK, PET and PI implanted with 80 keV Fe+ ions to high fluencies

  • Original language description

    olyimide (PI), polyetheretherketone (PEEK) and polyethylene terephthalate (PET) foils were implanted with 80 keV Fe+ ions at room temperature at fluencies of 0.2 x 10(16) cm(-2)- 5.0 x 10(16) cm(-2). The implanted polymers were subsequently annealed at 200 degrees C for 20 min. The depth profiles of implanted Fe atoms and compositional changes of the implanted polymers were characterised by RBS and ERDA methods. A significant shift of the Fe concentration maximum to the sample surface with increasing ion fluence was observed and annealing does not influence the Fe profiles. The implanted Fe profiles cannot be reproduced by SRIM and TRIDYN simulations. Hydrogen desorption from the surface layer of all polymers is observed, the effect being the most pronounced on PET. Desorption of oxygen from the samples implanted to lower fluences is observed too. On the samples implanted to the highest fluence of 5.0 x 10(16) cm(-2), however, oxygen concentration increases to the value close to that o

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    BG - Nuclear, atomic and molecular physics, accelerators

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2014

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Nuclear Instruments & Methods in Physics Research Section B

  • ISSN

    0168-583X

  • e-ISSN

  • Volume of the periodical

    331

  • Issue of the periodical within the volume

    JUL

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    6

  • Pages from-to

    176-181

  • UT code for WoS article

    000339144600037

  • EID of the result in the Scopus database