All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Characterisation of Channel Waveguides Fabricated in an Er3+-Doped Tellurite Glass Using Two Ion Beam Techniques

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389005%3A_____%2F22%3A00560658" target="_blank" >RIV/61389005:_____/22:00560658 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/chemosensors10080337" target="_blank" >https://doi.org/10.3390/chemosensors10080337</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/chemosensors10080337" target="_blank" >10.3390/chemosensors10080337</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Characterisation of Channel Waveguides Fabricated in an Er3+-Doped Tellurite Glass Using Two Ion Beam Techniques

  • Original language description

    Two methods were proposed and implemented for the fabrication of channel waveguides in an Er-doped Tellurite glass. In the first method, channel waveguides were fabricated by implanting 1.5 MeV and 3.5 MeV energy N+ ions through a special silicon mask to the glass sample at various fluences. Those waveguides implanted at a fluence of 1.0 x 10(16) ions/cm(2) operated up to 980 nm, and showed green upconversion of the Erbium ions. In the second method, channel waveguides were directly written in the Er3+: TeO2W2O3 glass using an 11 MeV C4+ ion microbeam with fluences in the range of 1 . 10(14)-5 . 10(16) ions/cm(2). The waveguides worked in single mode regime up to the 1540 nm telecom wavelength. Propagation losses were reduced from the 14 dB/cm of the as-irradiated waveguides by stepwise thermal annealing to 1.5 dB/cm at lambda = 1400 nm.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20501 - Materials engineering

Result continuities

  • Project

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2022

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Chemosensors

  • ISSN

    2227-9040

  • e-ISSN

    2227-9040

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    8

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    17

  • Pages from-to

    337

  • UT code for WoS article

    000846098700001

  • EID of the result in the Scopus database

    2-s2.0-85137403308