Magnetic beads-based electrochemical immunosensor for monitoring allergenic food proteins
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389013%3A_____%2F15%3A00445033" target="_blank" >RIV/61389013:_____/15:00445033 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.ab.2015.04.037" target="_blank" >http://dx.doi.org/10.1016/j.ab.2015.04.037</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ab.2015.04.037" target="_blank" >10.1016/j.ab.2015.04.037</a>
Alternative languages
Result language
angličtina
Original language name
Magnetic beads-based electrochemical immunosensor for monitoring allergenic food proteins
Original language description
Screen-printed platinum electrodes as transducer and magnetic beads as solid phase were combined to develop a particle-based electrochemical immunosensor for monitoring the serious food allergen ovalbumin. The standard arrangement of enzyme-linked immunosorbent assay became the basis for designing the immunosensor. A sandwich-type immunocomplex was formed between magnetic particles functionalized with specific anti-ovalbumin immunoglobulin G and captured ovalbumin molecules, and secondary anti-ovalbuminantibodies conjugated with the enzyme horseradish peroxidase were subsequently added as label tag. The electrochemical signal proportional to the enzymatic reaction of horseradish peroxidase during the reduction of hydrogen peroxide with thionine as electron mediator was measured by linear sweep voltammetry. The newly established method of ovalbumin detection exhibits high sensitivity suitable for quantification in the range of 11 to 222 nM and a detection limit of 5 nM. Magnetic beads-
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GAP206%2F12%2F0381" target="_blank" >GAP206/12/0381: Development of ultrasensitive electrochemical immunosensors for early detection of clinically significant biomarkers of malignant diseases</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical Biochemistry
ISSN
0003-2697
e-ISSN
—
Volume of the periodical
484
Issue of the periodical within the volume
1 September
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
4-8
UT code for WoS article
000357967500002
EID of the result in the Scopus database
2-s2.0-84934969110