Bactericidal effects in water sprayed through transient spark in air and related formation of ROS and RNS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61389021%3A_____%2F12%3A00386772" target="_blank" >RIV/61389021:_____/12:00386772 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Bactericidal effects in water sprayed through transient spark in air and related formation of ROS and RNS
Original language description
Chemical and bio-decontamination effects induced by plasma in water upon electro-spraying through DC-driven positive transient spark discharge in air were investigated. Inactivation of Escherichia coli in plasma treated water was determined in dependenceon the solution pH (controlled by buffers) and correlated with chemical changes in water upon treatment by plasma. Productions of H2O2, nitrites, nitrates, peroxynitrites and pH changes were determined and the extent of oxidative stress induced in bacteria was evaluated by measuring the thiobarbituric acid reactive substances (TBARS). The degree of inactivation and oxidative damage of bacteria increased with increasing acidity of the solution. Acidic nitrites with H2O2 were determined as the most important bactericidal agents in water treated by air plasma.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
BL - Plasma physics and discharge through gases
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů