All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Validation of Sparse Sampling Strateies to Estimate Cyclosporine A Area Under the Concentation-Time Curve Using Either a Specific Radioimmunoassay or Hign-Performance Liquid Chromography Method

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F10%3AA110107H" target="_blank" >RIV/61988987:17110/10:A110107H - isvavai.cz</a>

  • Result on the web

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Validation of Sparse Sampling Strateies to Estimate Cyclosporine A Area Under the Concentation-Time Curve Using Either a Specific Radioimmunoassay or Hign-Performance Liquid Chromography Method

  • Original language description

    Area under the concentration-time curve (AUC) has been advocated as a better parameter to monitor cyclosporine A than trough concentrations. U to now, more thal 100 equations to estimate AUC using a limited sampling strategy have been published, but nothave been validated. Eight equations for AUC o-12h and two for AUC 0-8h were validated. Concetrations of cyclosporine A were analyzed by high-performance liquid chromatograhpy (HPLC) and a specific radioimmunoassay (RIA) method. Forty male renal transplant patients were included in the study. Blood samples were taken predose and at 0,5, 1, 1,5, 2, 3, 5, 8, and 12 hours after the morning dose when the patient was in steady state. The percentage prediction error (%pe) was used for an assessment of the performance of the equations. Mean %pe less than +/- and absolute %pe lees than 30% in 95% of predictions were considered to be acceptable. Other possibilities such as %pe less than 25%, 20ˇand 15ˇwere also tested.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FR - Pharmacology and apothecary chemistry

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach

Others

  • Publication year

    2010

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    THER DRUG MONIT

  • ISSN

    0163-4356

  • e-ISSN

  • Volume of the periodical

    32

  • Issue of the periodical within the volume

    5

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    8

  • Pages from-to

  • UT code for WoS article

  • EID of the result in the Scopus database